Check code
Indication on 7-segment display on the outdoor unit
Auxiliary code
A26
Detected High-temperature Hot water module address
A27
Detected High-temperature Hot water module address
A28
Detected High-temperature Hot water module address
E06
Number of indoor units which received normally
E07
E08
Duplicated indoor addresses
E11
Detected High-temperature Hot water module address
01: Communication between indoor and outdoor units
E12
02: Communication between outdoor units
E15
00: Capacity over
E16
01~: Number of connected units
00: Header is nothing
E19
02: 2 or more header units
01: Other line outdoor connected
E20
02: Other line indoor connected
E23
E25
E26
Number of outdoor units which received normally
E28
Detected outdoor unit No.
(*1)
E31
IPDU quantity information
E31
80
F04
F05
01: TE1 sensor
F06
02: TE2 sensor
F07
01: TL1 sensor
F08
01: TS1 sensor
F12
02: TS2 sensor
01: Compressor 1
F13
02: Compressor 2
F15
F16
F23
F24
F31
01: Compressor 1
H01
02: Compressor 2
01: Compressor 1
H02
02: Compressor 2
01: Compressor 1
H03
02: Compressor 2
H05
H06
65-EN
Check code name
Gas leak detection
High-pressure protective operation
P.C. board communication trouble between I/F and
IPDU.
Decrease of number of indoor units
Indoor / outdoor communication circuit trouble
Duplication of indoor addresses.
P.C. board communication trouble between I / F and
Main.
Automatic addressing start trouble
No indoor unit during automatic addressing
Capacity over / number of connected indoor units
Number of header outdoor unit trouble
Other lines connected during automatic addressing
Communication transmission trouble between outdoor
units
Duplicated follower outdoor address set up
Decrease of connected outdoor units
Follower outdoor unit trouble
IPDU communication trouble
Communication trouble between MCU and sub MCU
TD1 sensor trouble
TD2 sensor trouble
TE1 sensor trouble
TE2 sensor trouble
TL1 sensor trouble
TO sensor trouble
TS1 or TS2 sensor trouble
TH (Heat sink) sensor trouble
Outdoor temp. sensor miswiring (TE1, TL1)
Outdoor pressure sensor miswiring (Pd, Ps)
Ps sensor trouble
Pd sensor trouble
Outdoor EEPROM trouble
Compressor breaking down
Compressor trouble (Locked)
Current detection circuit trouble
TD1 sensor miswiring
Low pressure protective operation
– 33 –
Check code
Indication on 7-segment display on the outdoor unit
Auxiliary code
H07
Detected outdoor unit No.
01: TK1 sensor trouble
02: TK2 sensor trouble
H08
04: TK4 sensor trouble
05: TK5 sensor trouble
H15
01: TK1 oil circuit trouble
02: TK2 oil circuit trouble
H16
04: TK4 oil circuit trouble
05: TK5 oil circuit trouble
J10
Detected indoor unit address
L02
Model mismatch of indoor and outdoor unit
L04
L06
Number of prior indoor units
L08
L10
L12
01: Flow selector unit(s) installation trouble
L17
L18
Detected indoor unit address
L23
01: Clean Converter setting trouble
01: Duplication of flow selector unit address
L24
02: Indoor unit(s) operation mode priority setting
L28
(*1)
L29
IPDU number information
L30
Detected indoor unit address
L31
P03
01: Compressor 1
P04
02: Compressor 2
01: Compressor 1
P05
02: Compressor 2
01: Compressor 1
P07
02: Compressor 2
P10
Detected indoor unit address
P13
01: TS condition
P15
02: TD condition
P17
P19
Detected outdoor unit number
P20
Check code name
Oil level down detection
(Indicated only on the header outdoor unit)
Temperature sensor trouble for oil level
TD2 sensor miswiring
Oil level detector circuit trouble
Flow selector units overflow trouble
System shutdown trouble from indoor unit
Outdoor system address duplication
Duplication of indoor units with priority
Indoor unit group / address unset
Outdoor unit capacity unset.
Flow selector unit(s) system trouble
Inconsistent models of outdoor units
Flow selector unit trouble
Setting trouble
Flow selector unit(s) setting trouble
Outdoor connected quantity over
IPDU quantity trouble
External interlock of indoor unit
Compressor IPDU trouble
Discharge temperature TD1 trouble
High-pressure SW system operation
Compressor Vdc trouble
AC detection circuit trouble
Heat sink overheat trouble
Indoor overflow trouble
Outdoor unit flow back trouble detected
Gas leak detection
Discharge temperature TD2 trouble
4-way valve inverse trouble
High-pressure protective operation
66-EN