Decrease Of Hot Water Flow - Electrolux GWH-275 R N Service Manual

Table of Contents

Advertisement

Decrease of hot water flow

Decrease of hot water flow?
no
Water tub
is free ?
yes
Water
no
supply
pressure
is OK ?
yes
no
Cold water
strainer is
free ?
yes
Heat
no
exchanger
is free ?
yes
Change the water
valve.
Clean the water tub.
Contact the water
supplier.
Clean the cold water
strainer
Clean or change the
heat exchanger.