Fire Sense 60368 Manual page 11

Outdoor patio heater
Hide thumbs Also See for 60368:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
lIGHTING
NOTE: For initial start or after any cylinder
change, hold the control knob in for 2
minutes to purge air from all gas lines
before proceeding.
1. Turn the control knob to the "OFF"
position.
2. Fully open the LPG tank valve.
3. Push in and turn the control knob
to HI symbol.
4. Keep the control knob depressed
and then push the RED igniter button
simultaneously, push several times to
ignite the main burner. Repeat until the
burner ignites. Keep the control knob
fully depressed for an additional 30
seconds after the burner ignites, then
release the control knob.
5. To increase the flame, turn the control
knob clockwise towards HI. To
decrease the flame, turn the control
knob counter-clockwise towards LO.
6. To turn the appliance OFF, depress the
control knob and turn clockwise to the
OFF position.
7. Wait at least 5 minutes before
attempting to re-light the heater.
8. Turn the LPG tank valve to OFF
or closed. If you experience any
ignition problems, please consult
"Troubleshooting" on page 16.
Caution: Avoid inhaling fumes emitted from the heater's first use. Both
smoke and odor from the burning of oils used in the manufacturing will
appear. Both smoke and odor will dissipate after approximately 30 minutes.
The heater should NOT produce thick black smoke.
If you experience any ignition problems, please consult "Troubleshooting"
on page 14. Caution: Avoid inhaling fumes emitted from the heater's first
use. Smoke and odor from the burning of oils used in the manufacturing
will appear. Both smoke and odor will dissipate after approximately
30 minutes. The heater should NOT produce thick black smoke.
Contact us for assistance: (866) 985-7877 | www.wtliving.com
FOR YOUR SAFETY
Be careful when attempting to manually
PUSH IN
ignite this heater. Holding in the control
knob for more than 10 seconds before
igniting the gas will cause a ball of flame
upon ignition.
WHEN HEATER IS ON:
Emitter screen will become bright
red due to intense heat. The color
is more visible at night. Burner will
display tongues of blue and yellow
flames. These flames should not
be yellow or produce thick black
PUSH &
smoke, indicating an obstruction
HOlD
of airflow through the burners. The
flame should be blue with straight
yellow tops. If excessive yellow
WHIlE
flame is detected, turn off heater
and consult "Troubleshooting" on
PUSHING
page 14.
IN BUTTON
RE-lIGHTING:
Note: For your safety, the control
knob cannot be turned OFF
without first depressing the
control knob and then rotating
to OFF.
1. Turn control knob to OFF.
2. Wait at least 5 minutes to
allow gas to dissipate before
re-lighting.
3. Repeat the "Lighting" steps
listed above.
WARNING
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents