Troubleshooting Guide - Heath Zenith 5525 Operating Instructions Manual

Motion sensing halogen fixture
Table of Contents

Advertisement

Available languages

Available languages

Light
Shield
SYMPTOM
POSSIBLE CAUSE
Light will not come on.
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
Light comes on in day-
1. Light control may be installed in a relatively dark
light.
2. Light control is in TEST.
Light comes on for no
1. Light control may be sensing small animals or auto-
apparent reason.
2. Range is set too high.
Light stays on continu-
1. A lamp is positioned too close to the light control or
ously.
2. The light control may be picking up a heat source
3. Light control is in manual mode.
Light flashes on and
1. Heat or light from the lamps may be turning the light
off.
2. Heat being reflected from other objects may be turn-
3. Light control is in the TEST mode and warming up.
4. If eave installation, light shield not installed properly.
Light flashes once, then
Light control is detecting its own lights.
stays off in manual
mode.
204055-02
Protective
Backing

TROUBLESHOOTING GUIDE

location.
mobile traffic.
pointed at nearby objects that cause heat to trigger
the light control.
like an air vent, dryer vent, or brightly painted, heat-
reflective surface.
control on and off.
ing the light control on and off.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 250 Watts Maximum
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T3, 250W (or less) halogen
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
SOLUTION
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these condi-
tions.
2. Set control switch to 1, 5, or 10 minutes.
1. Re-aim light control.
2. Reduce range.
1. Reposition the lamp away from the light control or
nearby objects.
2. Re-aim light control. Reduce range.
3. Switch light control to AUTO.
1. Reposition the lamp away from the light control.
2. Reposition light control.
3. Flashing is normal under these conditions.
4. Install light shield according to instructions.
Reposition lamp to keep area below the light control
relatively dark.
5
surrounding temperature].
Incandescent.
MODE
120 VAC

Advertisement

Table of Contents
loading