System Description; Overview; Table 1-1 Xfc Family Genealogy - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

1 System description

1.1

Overview

The XFC
generation 3 XFC6200/6201EX. The G4 EX now incorporates the same 32-bit
technology currently used by the G4 XSeries products. By using 32-bit technology,
Windows
offering for production automation and DIV 1 custody measurement projects.
Along with this new functionality, the hardware capabilities are expanded to meet
the demands of targeted market applications in production automation and natural
gas distribution. These hardware features will be utilized to enhance the system
integration capabilities with existing Totalflow products as well as existing third-
party control SCADA systems. Additionally, the use of Bluetooth technology for
local MMI connectivity is poised to enhance the product for multi-tube and Class 1,
DIV 1 applications where this type of user interface is an advantage.
The G4 EX offers an explosion-proof product for differential (orifice) or linear
(pulse) metering and automation systems. The G4 EX is an accurate and reliable
gas flow computer with the capability to measure and monitor gas flow in
compliance with AGA, API and ISO standards.
The G4 EX is a low power, microprocessor-based unit designed to meet a wide
range of measurement, control, monitor and alarming applications for remote gas
systems located in DIV 1 hazardous areas.
See Table 1–1 for the XFC family genealogy. This highlights the main differences
between the various devices.
XFC
DIV
Multi
Model
Class
Tube
6200EX
1
6201EX
1
6410
2
6411
2
6413
2
6414
2
6713
2
6714
2
2104349 rev. AD
G4
6200/6201EX (G4 EX) is a next generation solution for the pre-existing
®
CE OS and memory capabilities, the G4 EX is a versatile product
The XFC G4 6200/6201EX (G4 EX) is approved for installation
in Classified/Potential Hazardous Locations where an
explosive atmosphere may be present. Follow precautions and
requirements for installation, maintenance and service of
equipment according to Local and National Electrical Codes
and the "Warnings" contained in this manual.
Table 1–1 XFC family genealogy
Orifice
Pulse
Battery
Meter
Meter
Charger
External
External
On board
On board
On board
On board
On board
On board
Max.
Communication
Battery
Equipment
Capacity
External
External
External
External
26AH
External
26AH
External
26AH
Internal
26AH
Internal
42AH
Internal
42AH
Internal
Max. TFIO
Modules
12-Point I/O Opt.
Expansion Card
12-Point I/O Opt.
Expansion Card
N/A
N/A
3
3
6
6
Page 1–1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries g4 6201ex

Table of Contents