Figure 4-9 Termination Board Secondary Component Side - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

4) Gain access to the rear termination board by loosening the countersunk hex
5) Upon unscrewing the end cap, the user will see the termination board (see
6) Depending on the configuration that the user selected from the factory,
7) Next, remove the Comm 1 (J19), Comm 2 (J20) and power (J16)
8) Upon completion, remove the ribbon cable from the J1 connector (Figure 4–
9) Take the replacement termination board and attach the ribbon cable to the
10) Depending on the configuration that the user selected from the factory,
11) Next, attach the Comm 1 (J19), Comm 2 (J20) and power (J16) connections
12) Upon completion, take the four socket mounting screws, and attach the
Page 4–14
socket locking set screw in the rear end cap. Use a 1/16" hex wrench to
perform this task. Upon completion, unscrew the end cap.
Figure 4–5). Using a ¼" socket wrench, unscrew the four socket mounting
screws that hold the termination board in place.
remove either the USB cable (J4), Ethernet cable (J7) or MMI cable (J21).
connectors.
9). This will enable the user to remove the termination board from the G4
EX device.
Figure 4–9 Termination board secondary component side
J1 connector.
Please note that the ribbon cable pin 1 wire is red. The red
edge (pin 1) of the cable should plug into the outer most
edge of the connector (pin 1).
attach either the USB cable (J4), Ethernet cable (J7) or MMI cable (J21) to
their respective connection.
to their respective connectors.
termination board in the G4 EX device.
2
50
49
1
J1
2104349 rev. AD