PROBLEM SOLVING

The A 1000 / A 2000 is designed and manufactured for severe environments and tasks, but the user must note that the machine
components must be protected from knocks and blows. Filter and sealing connections are carefully chosen to serve the operator.
Therefore, the machine must be handled with care if it is to work correctly for many years.
Problem
The fan does not start
The fan stops immediately
The fan runs, but suction is poor
Dust blows from unit
Abnormal noise

TECHNICAL DATA

Power, kW
Voltage, V
Current, A
Power supply
Airflow, m3/h
Airflow, CFM
Weight, kg
Weight, lbs
Dimensons, mm
Dimensions, in
Hepa-Filter, m2
HEPA filter, ft2
Cause
No power
Cable defective
Switch defective
Wrong fuse
Blocked filter
Cover loose
Sealing defect
Defective or loose filter
Keep these instructions!
A 2000 (230V)
0,75
230
3,3
1-phase
1000/2000
600/1200
38
84
724x424x810
28,5x16,7x31,9
10,5
150
Procedure
Connect the machine
Change
Change
Connect the correct fuse
Change filter
Adjust
Change current seal
Adjust or change
Order service
A 2000 (120V)
A 1000 (230V)
0,585
120
4,9
1-phase
1000/2000
600/1200
38
84
724x424x810
465x385x466
28,5x16,7x31,9
18,3x15,1x18,3
10,5
150
A 1000 (120V)
0,285
230
1,2
1-phase
1-phase
500/1000
500/1000
300/600
300/600
20
44
465x385x466
18,3x15,1x18,3
3,5
60
0,385
120
3,2
20
44
3,5
60

Hide quick links: