8.5.1 Inclinometer-controlled Thrust Run-Out
Inclinometer control during the thrust Run-Out procedure is used to measure more
accurately the rotation angle pertaining to the calculation.
From the Run-Out configuration menu, set – Thrust Run-Out
Lower the reference detector (usually it is the left front one) until its end is almost touching
the ground, then lock it in place. RELEASE the other detectors, so that they are free to
oscillate upon wheel movement. When finished, press central key to confirm.
Move vehicle back, very slowly, until reference sensor reaches the target position (end up -
see Figure 38). When finished, press central key to confirm.
Vehicle thrust
direction (back)
Position reference sensor horizontally - clearly levelled - and, when finished, press central key
to confirm.
RAVTD1760 WS – RAVTD1780 WS
Figure 37
Figure 38
RAVAGLIOLI S.p.A. - Via I° Maggio, n° 3 (Pontecchio Marconi)
40037 Sasso Marconi (Bologna - Italy)
Tel. 051/ 67.81.511 – Fax 051/ 84.64.67 E-mail: rav@ravaglioli.com
Instruction manual
Code M0197 - rev.1.0
"inclinometer".
Vehicle
starting point
Reference
sensor start
position
Vehicle target
point
Reference
sensor target
position
Page 29/52
(11/2010)