BLUEHELIX TECH RRT 24 C

Cleaning or replacing the flowmeter

Before carrying out the following instructions it is advisable to protect the area and the boiler's PCB housing
A
against accidental water spillage.
5
Isolate the power supply and close the Gas isolation valve to the boiler.
Remove the diverter valve motor head (see fig. 47).
Close the cold water inlet isolation valve and open a hot water tap in the property
Release the retaining clip "4" and remove the flowmeter assembly "5" by pulling upwards.
The flowmeter components can thus be cleaned or replaced (see fig. 50 and fig. 51).

Wash the filter with clean water.

EN
4
fig. 49- Flowmeter
fig. 50
cod. 3541P250 - Rev. 01 - 07/2018
1 - Flow-rate limiter
2 - Impeller
3 - Filter
4 - Clip
5 - Flowmeter
1
2
3
Lubricate the flowmeter 'o ring seals with silicone grease.
fig. 51