BLUEHELIX TECH RRT 24 C
Cleaning or replacing the flowmeter
Before carrying out the following instructions it is advisable to protect the area and the boiler's PCB housing
A
against accidental water spillage.
5
•
Isolate the power supply and close the Gas isolation valve to the boiler.
•
Remove the diverter valve motor head (see fig. 47).
•
Close the cold water inlet isolation valve and open a hot water tap in the property
•
Release the retaining clip "4" and remove the flowmeter assembly "5" by pulling upwards.
•
The flowmeter components can thus be cleaned or replaced (see fig. 50 and fig. 51).
Wash the filter with clean water.
EN
4
fig. 49- Flowmeter
fig. 50
cod. 3541P250 - Rev. 01 - 07/2018
1 - Flow-rate limiter
2 - Impeller
3 - Filter
4 - Clip
5 - Flowmeter
1
2
3
Lubricate the flowmeter 'o ring seals with silicone grease.
fig. 51
41