Removing the diverter valve motor head

Before carrying out the following instructions it is advisable to protect the area and the boiler's PCB housing
A
against accidental water spillage.
Isolate the power supply and close the Gas isolation valve to the boiler.
Remove the diverter valve electrical connection.
Remove the spring clip "1" and remove the diverter valve "2".
Replace in reverse order.

Replacing the Low water pressure switch

Before carrying out the following instructions it is advisable to protect the area and the boiler's PCB housing
A
against accidental water spillage.
Isolate the power supply and close the Gas isolation valve to the boiler.
Turn off the Flow & Return isolation valves & drain the boiler (see system draining fig. 16).
Remove the electrical connection "1" and fastening spring clip "2".
Remove the water pressure switch "3".
Clean or replace the LWP switch then apply silicone grease to the 'O' ring before replacing.
40
BLUEHELIX TECH RRT 24 C
2
1
fig. 47
3
1
2
fig. 48
cod. 3541P250 - Rev. 01 - 07/2018