Exchanger insulation replacement

Isolate the power supply and close the Gas isolation valve to the boiler.
Remove the cover of the heat exchanger and the burner (see fig. 43 Removing the burner and cleaning the heat
exchanger).
Remove the ignition electrode (2 x T15 Torx screws) Take care not to damage the gasket, replace if damaged. "1".
Rotate the insulating disc "2" and remove it, (Dispose of the damaged insulation pad safely this cannot be reused)
Install the new insulation pad to the heat exchanger ensuring its correctly secured to the tab the reassemble the
boiler.

Fan

2
Isolate the power supply and close the Gas isolation valve to the boiler.
Remove the electrical connection to the fan.
Remove the clamp "1" and undo & remove the screws "2".
Remove the fan "3" & replace the gasket if damaged.
When installing / replacing a fan a combustion calibration must be carried out (see "100% calibration" on page 23).
38
BLUEHELIX TECH RRT 24 C
3
2
1
3
fig. 44
cod. 3541P250 - Rev. 01 - 07/2018