Binks 0811-7500-4 Service Manual
Binks 0811-7500-4 Service Manual

Binks 0811-7500-4 Service Manual

Airless 75m spray gun 7500 psi
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

SERVICE MANUAL
EN
AIRLESS 75M SPRAY GUN
7500 PSI
(0811-7500-4)
The following instructions provide the necessary information for the proper
operation and preventive maintenance of the Binks Airless 75M Spray Gun.
Please read and understand all information in this document in order to get the
maximum performance from your new Airless 75M spray gun.
IMPORTANT! DO NOT DESTROY
It is the customer's responsibility to have all operators and service personnel
read and understand this manual.
Contact your local Binks representative for additional copies of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THIS BINKS PRODUCT.
77-3084-R2.2 (7/2016)
1 / 14

Advertisement

Table of Contents
loading

Summary of Contents for Binks 0811-7500-4

  • Page 1 (0811-7500-4) The following instructions provide the necessary information for the proper operation and preventive maintenance of the Binks Airless 75M Spray Gun. Please read and understand all information in this document in order to get the maximum performance from your new Airless 75M spray gun.
  • Page 2 Product Description/Object of Declaration: Airless 75 Guns This Product is designed for use with: Solvent and Water based Materials Suitable for use in hazardous area: Zone 1 Protection Level: II 2 G X Notified body details and role: Element Materials Technology. WN8 9PN UK Lodging of Technical file This Declaration of Conformity Carlisle Fluid Technologies,...
  • Page 3 Inspect the equipment for worn or broken parts THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT. on a daily basis. Do not operate the equipment FOR FURTHER SAFETY INFORMATION REGARDING BINKS if you are uncertain about its condition. AND DEVILBISS EQUIPMENT, SEE THE GENERAL EQUIPMENT SAFETY BOOKLET (77-5300).
  • Page 4: Specifications

    BINKS AIRLESS 75M SPRAY GUN 7500 PSI For trained, professional use only! Maximum working pressure: 7500 PSI – 517 BAR – 51.7 Mpa Model 0811-7500-4 SAFETY, OPERATING AND MAINTENANCE INSTRUCTIONS INSIDE!! Read all warnings and operating information inside SAVE THIS MANUAL FOR FUTURE...
  • Page 5 BINKS AIRLESS 75M SPRAY GUN CAUTION NOTE NOTE TO PHYSICIAN: KEEP CLEAR OF NOZZLE: Do not exceed Injection into the skin is a traumatic injury. maximum working pressure of 7500 PSI It is important to treat the injury as soon as (517 BAR, 51.7 Mpa).
  • Page 6 BINKS AIRLESS 75M SPRAY GUN Hold gun firmly against side of container to WARNING ground container and prevent static sparks. Follow the material and solvent manufacturer’s HAZARD: GENERAL – Can cause severe warnings and instructions. injury or property damage. Use extreme caution when using materials with a PREVENTION: flashpoint below 70°...
  • Page 7 BINKS AIRLESS 75M SPRAY GUN Do not point gun at anyone or any part of the WARNING body. Do not put your hand or fingers over the spray tip. The following are general WARNINGS Do not stop or deflect leaks with your hand, related to the setup, use, grounding, body, glove or rag.
  • Page 8 Do not kink or over bend hoses or use hoses to pull equpment. Never attempt to assemble, change, or Use genuine BINKS hoses. If provided, do not clean the gun, tip, or tip guard without first remove the spring guards from hoses, these are relieving pressure from the spray system.
  • Page 9: Gun Operation

    3/8-18 NPS THREAD LOCKED UNLOCKED If you are using a genuine BINKS tip, follow the GUN OPERATION instructions below to install the guard and tip. If you are using a different tip, follow the 1. Make sure your tip is in the spray position.
  • Page 10: Troubleshooting

    BINKS AIRLESS 75M SPRAY GUN TO REPLACE NEEDLE ASSEMBLY (10) NOTE 1. Shut off power supply to pump and release If clog is not completely expelled after pressure from gun. Remove gun from hose. following the above steps, repeat steps 1-4 2.
  • Page 11 BINKS AIRLESS 75M SPRAY GUN BINKS AIRLESS 75M SPRAY GUN PARTS LIST ITEM PART NUMBER DESCRIPTION QTY. — TWIST TIP 7500, PSI, SEE CHART 54-7539-K2 AIRLESS 75 TWIST TIP BRACE KIT 1108-75B 7500 PSI TWIST TIP GUARD 54-7537-K DIFFUSER NUT KIT...
  • Page 12 BINKS SPRAY TIP SELECTION CHART PART NUMBER 9-XXX-75 (Tips rated for use at 7500 psi) All of the following tips will have a grey tip handle 4” 6” 8” 10” 12” 14” spray spray spray spray spray spray pattern pattern...
  • Page 13 NOTES 77-3084-R2.2 (7/2016) 13 / 14...
  • Page 14: Warranty Policy

    WARRANTY POLICY Binks products are covered by Carlisle Fluid Technologies one year materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. For specific warranty information please contact the closest Carlisle Fluid Technologies location listed below.
  • Page 15 Pistola pulverizadora sin aire 75M de Binks. Sírvase leer y comprender toda la información contenida en este documento para lograr el máximo nivel de desempeño de su nueva Pistola pulverizadora sin aire 75M.
  • Page 16 Descripción del producto / Objeto de la Declaración : Airless 75 Guns Este Producto está diseñado para su uso Materiales de base de agua y disolventes con: Adecuado para su uso en áreas peligrosas: Zona 1 Nivel de protección: II 2 G X Notificado de carrocería y papel : Element Materials Technology.
  • Page 17 Inspeccione diariamente los equipos para PARA MÁS INFORMACIÓN DE SEGURIDAD ACERCA DE LOS verificar que no tengan piezas gastadas o rotas. EQUIPOS BINKS Y DEVILBISS, No opere los equipos si no está seguro de esta CONSULTE EL FOLLETO DE SEGURIDAD GENERAL DE LOS condición.
  • Page 18: Especificaciones

    PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS 7500 PSI ¡Únicamente para uso por personal capacitado y profesional! Presión de trabajo máxima: 7500 PSI – 517 BAR – 51.7 Mpa Modelo 0811-7500-4 !!INSTRUCCIONES DE SEGURIDAD, OPERACIÓN Y MANTENIMIENTO EN PÁGINAS INTERIORES!! Lea todas las advertencias y la información...
  • Page 19 PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS PRECAUCIÓN NOTA NOTA AL MÉDICO: MANTÉNGASE ALEJADO DE LA BOQUILLA: La inyección en la piel es una lesión No sobrepase la presión de trabajo máxima traumática. Es importante tratar la lesión de 7500 PSI (517 BAR, 51.7 Mpa).
  • Page 20 PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS PREVENCIÓN: Siempre descargue la unidad en un recipiente metálico separado, a una presión de bomba baja, Use un respirador o máscara si existiese la posibilidad habiendo quitado la punta pulverizadora. de inhalar vapores. Lea todas las instrucciones Sostenga la pistola con firmeza contra el costado provistas con la máscara para asegurarse de que...
  • Page 21 Busque de inmediato tratamiento quirúrgico. Informe a su médico Use el equipo únicamente para el propósito para acerca del tipo de material que fue inyectado. el que fue fabricado. Llame a Binks para más información. 77-3084-R2.2 (7/2016) ES-7 / 14...
  • Page 22 Pistola pulverizadora sin aire de debida a la acumulación de estática o en caso de BINKS para la pistola de 7500 PSI (517 cortocircuito. Siga las instrucciones de conexión a BAR) son de color negro.
  • Page 23 ROSCA DE 3/8-18 NPS CON SEGURO SIN SEGURO Si usted está usando una punta genuina BINKS, siga las siguientes instrucciones para instalar el OPERACIÓN DE LA PISTOLA resguardo y la punta. Si está usando una punta diferente, siga las instrucciones provistas con la 1.
  • Page 24: Localización Y Reparación De Averías

    PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS Las pasadas sucesivas podrían requerir de NOTA superposición parcial. La superposición típica es del 30%. Si la obstrucción no se ha eliminado PARA REEMPLAZAR EL CONJUNTO DE LA totalmente después de seguir los pasos...
  • Page 25 PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS LISTA DE PIEZAS, PISTOLA PULVERIZADORA SIN AIRE 75M DE BINKS NÚM. NÚM. DE DESCRIPCIÓN CANT. PIEZA ART. — PUNTA GIRATORIA 7500, PSI, VER LA TABLA 54-7539-K2 KIT DE TRABA CON PUNTA GIRATORIA, SIN AIRE 75...
  • Page 26 TABLA DE SELECCIÓN DE PUNTAS DE ATOMIZADO BINKS NÚMERO DE PIEZA 9-XXX-75 (puntas clasificadas para uso a 7500 psi). Todas las siguientes puntas tendrán una manija gris Patrón de Patrón de Patrón de Patrón de Patrón de Patrón de pulverización pulverización...
  • Page 27 NOTAS 77-3084-R2.2 (7/2016) ES-13 / 14...
  • Page 28 POLÍTICA DE GARANTÍAS Los productos Binks están cubiertos por la garantía limitada de materiales y mano de obra por un año de Carlisle Fluid Technologies. El uso de cualquier pieza o accesorio de una fuente que no sea Carlisle Fluid Technologies, anulará todas las garantías. Para obtener información específica sobre la garantía, favor ponerse en contacto con el local de...

Table of Contents