Mira Montpellier Installation, Operation, Maintenance Manual page 14

Shower control
Table of Contents

Advertisement

Installation
1.
Decide on a suitable position for the
mixer and the shower rose where all
users can operate it.
Note! longer riser pipe is not available.
2.
Remove wall backplate from rear of
mixer by loosening grubscrew with
hexagon key (supplied) on the
underside of mixer.
3.
Use backplate to mark 3 hole
positions. Drill wall and insert wall
plugs (supplied).
4.
Locate inlet nuts, plates and olives
flush against the wall. Locate valve on
inlet pipes (the inlet pipes must
protrude a maximum of 18.5 mm from
the finished wall surface) and wall
backplate. Inlet nuts must be tightened
whilst doing this to pull the valve onto
the backplate. Use the hexagon key
(supplied) to tighten grubscrew on the
underside of the mixer.
5.
Loosely assemble the shorter piece of
riser piper to the valve body with the
support bracket fitted. Make sure that
the riser pipe is vertical and mark the
position of the fixing hole.
6.
Drill and insert wall plug (supplied).
7.
Assemble the riser pipe and fix support
bracket to the shower valve.
8.
Install the divertor valve onto the riser
pipe.
Note! The divertor valve must be
fitted with its outlet connection on
the left, otherwise restricted flow will
occur.
Wall Backplate
Inlet Pipes
Support Bracket
14
Wall Plugs
Fixing Screws
Wall Bracket
Fixing Screw
Divertor Valve
Support Bracket

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents