Mira Realm - Mira REALM Installation And User Manual

Thermostatic mixer
Table of Contents

Advertisement

Mira Realm

1. The thermostatic mixer can be installed with
rear, rising or falling supply inlets. Decide
on the most appropriate method for your
installation, and if necessary, the inlet elbows
can be swivelled to suit.
2. Use the installation template to mark the
positions of the holes for the backplate and
the pipe centres.
For rising or falling supplies the pipe positions
should be set 35 mm from the centre of pipe
to the finished wall at 153 mm centres.
35 mm
3. For solid walls drill the holes for the backplate
with a 6 mm drill and insert the wall plugs.
Note! For other types of wall structure
alternative fixings may be required (not
supplied).
6 mm Drill
4. For Rear Entry Supplies Only:
a)
Drill the holes for the supply pipes at
153 mm centres.
b)
Recess the inlet holes Ø 19 mm x 2 mm
deep to allow for the concealing plates.
5. Fit the supply pipework: Hot - Left, Cold
- Right. For rear entry supplies the inlet
pipework should extend 28 mm from the
finished wall surface, for rising or falling
supplies the centre of the pipe should be set
35 mm from the finished wall surface.
Note! If it is not possible to install the mixer
with this pipework configuration complete the
installation then refer to section: 'Reversed
Inlet Supplies'.
Elbow
HOT
Diameter 19 mm
x 2 mm deep
6. Remove the backplate from the mixer by
loosening the grubscrew with a 2.5 mm
hexagonal key.
7. Secure the backplate to the wall using the
screws.
9
Wall Plug
28 mm from finished
wall surface
Ø19 mm
COLD
28 mm
153 mm