Backplate
8. For Rear Entry Supplies Only:
a)
Fit the concealing plates over the inlet
pipes.
Note! Apply silicone sealant to the back
face of the flange.
Apply Silicone Sealant
9. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer. Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
10. Fit the compression nuts and olives onto the
pipework.
11. Align the mixer with the pipework and fit onto
the backplate.
12. Tighten the compression nuts onto the mixer
with a suitable spanner.
Caution! Take care not to damage the chrome
surfaces.
13. Tighten the grubscrew to secure the mixer to
the backplate.
Screws
Concealing Plate
Horizontal Arm
14. Temporarily fit the rigid riser pipe and
horizontal arm and wall bracket to the shower
control outlet and mark the position of the wall
bracket. Use a spirit level to ensure the pipe
is vertical. Drill the holes and insert the wall
plugs.
Note! The vertical rigid riser pipe can be
shortened if required. De-burr the pipe ends
before making the final connection.
15. Fix the wall bracket, rigid riser pipe and tighten
the three compression fittings on the shower
control outlet and horizontal arm.
Note! Care must be taken when tightening
compression nuts so that you do not damage
the plated surfaces.
16. Turn on the hot and cold water supplies and
check for leaks.
17. Thoroughly flush the outlet pipework before
connecting the shower head. Slide the
compression nut and olive over the horizontal
arm and make the connection to the shower
head.
18. Before using the shower, refer to section:
'Commissioning'.
10
Wall Bracket
Rigid Riser
Pipe
Showerhead