Manual Operation; Programming Your Thermostat - White Rodgers 1F82-261 Installation And Operation Instructions Manual

Programmable electronic digital heat pump thermostat
Table of Contents

Advertisement

OPERATION
5) Select Energy Management Recovery OFF or ON - Energy
reach the program setpoint at the time you specify.
6) Select filter replacement run time - The thermostat will
display FLTR after a set time of operation. This is a reminder
0 to 1950 hours in 50 hour increments. A selection of 000
will cancel this feature.
clear it by pressing HOLD and RUN at the same time. This
7) Select Compressor Lockout LOC OFF or ON
turning on the compressor if the heating and cooling system
loses power. It will also wait 5 minutes minimum between
cooling or heating cycles. This is intended to help protect the
the thermostat compressor time delay occurs it will flash the
Snowflake and Flame
8) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display up to 4°
at the factory but you have the option to change the display
temperature to match your previous thermostat. The current
or adjusted room temperature will be displayed on the right
side of the display.
9) Select F° or C° Readout - Changes the display readout to
perature will be displayed on the right side of the display.
10) Select Fast second stage
perature is manually raised by 3°F ( 2°C) or more above
room temperature using
until the setpoint temperature is 10°F or more above room
temperature.
Heating/Cooling Schedule Plan (Factory Program)
WEEKDAYS
(5 Day)
Period
Time
Temp
1ST
70°F
2ND
62°F
3RD
70°F
4TH
62°F
1ST
78°F
2ND
85°F
3RD
78°F
4TH
82°F
FLTR
and the fast second stage
SAMPLE
SATURDAY
SUNDAY
(1 Day)
(1 Day)
Time
Temp
Time
70°F
62°F
70°F
62°F
78°F
85°F
78°F
82°F

MANUAL OPERATION

HOLD TEMPERATURE
HEAT or COOL,
will be displayed. Use
ture. The thermostat will hold the room temperature at the
selected setting until you press RUN button to start program
operation again.
TEMPERATURE OVERRIDE — Press
temperature you want is displayed. The thermostat will over-
begins. Then the thermostat will automatically revert to the
program.
TEMPORARY HOLD TEMPERATURE — The thermostat
can hold any temperature within its range for the length of

PROGRAMMING YOUR THERMOSTAT

This section will help you plan your thermostat's program to
the following guidelines in mind when planning your program.
tures to be cooler (warmer) when the building is vacant or
during periods of low activity.
minimal.
Planning Your Program
shown in the sample schedule. If this program will suit your
-
preset program.
-
If you want to change the preprogrammed times and tempera-
Determine the time periods and temperatures for your program.
use the same heating and cooling temperatures for consecutive
Heating/Cooling Schedule Plan
WEEKDAYS
Period
Time
Temp
1ST
70°F
2ND
62°F
3RD
70°F
4TH
62°F
1ST
78°F
2ND
85°F
3RD
78°F
4TH
82°F
6
or
to adjust the tempera-
SATURDAY
(1 Day)
(5 Day)
Temp
Time
Temp
HOLD
or
until the
-
SUNDAY
(1 Day)
Time
Temp

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents