OPERATION

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate
Turn on power to the system.
Fan Operation
If your system does not have a G
Heating System.
ON position. The blower should begin to
operate.
AUTO position. The blower should stop
immediately.
Heating System
2. Press
to adjust thermostat setting to 1° above room
temperature. The Heat Pump system should begin to operate.
Flame icon ( ) and Snowflake icon ( ) are
3. Adjust temperature setting to 4° above room temperature.
Flame icon will be flashing.
4. Press
to adjust temperature setting below room tem-
perature. The heating system should stop operating.
Emergency System
heat only.
on the display.
2. Press
to adjust the thermostat above room temperature.
icon (
is operating.
3. Press
to adjust the thermostat below room temperature.
Cooling System
!
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
2. Press
to adjust thermostat setting below room tempera-
followed by cold air circulation
3. Press
to adjust temperature setting above room tem-
perature. The cooling system should stop operating.
HEAT
CAUTION
COOL position.
Do not allow the compressor to run unless the
compressor oil heaters have been operational for 6
hours and the system has not been operational for at
least 5 minutes.
familiar with its features and with the display and the location and
two parts: the thermostat cover and the base. To remove the
line up the cover with the base and press until the cover snaps
onto the base.
THE THERMOSTAT BASE
The Thermostat Buttons and Switches
1 Raises temperature setting.
2 Lowers temperature setting.
3
4
5 RUN (program) button.
6
7 FAN switch (ON AUTO).
8
9
10 Indicates a malfunction with the system.
Flame
TIME
3
9
MO TU WE TH FR
FLTR
16
13
Figure 5. Thermostat display, buttons, and switches
4
CAUTION
!
and
COOL OFF HEAT, EMER).
The Display
FAN
PRGM
RUN
HOLD
ON
AUTO
COOL
Fltr
4
5
6
7
AM
HOLD
15
11
14
2
OFF HEAT
EMER
8
9
10
SA
SU
MALF
PM
EMER
13
12
11

Hide quick links: