I/O Controls Category
The Calibir GigE I/O controls, as shown by CamExpert, groups features used to configure an
external trigger input and acquisition actions based on the trigger. For more information on
connecting an external trigger input, see the 10-pin I/O Connector Details section.
I/O Controls Feature Descriptions
Table 12 describes these features along with their view attribute. Additionally the View column will
indicate which feature is a member of the DALSA Features Naming Convention (indicated by
DFNC), versus the GenICam Standard Features Naming Convention (SFNC tag is not shown).
Table 13: I/O Controls Feature Descriptions
Display Name
Trigger Selector
Frame Acquisition Trigger
Trigger Mode
External trigger
Trigger Frames Count
Software Trigger
Trigger Source
Line 0
Calibir 640 GigE IR Camera User's Manual
Figure 33: CamExpert I/O Controls Category
Feature & Values
TriggerSelector
AcquisitionStart
TriggerMode
Off
triggerFrameCount
TriggerSoftware
TriggerSource
Description
Selects which type of trigger to configure with the
various Trigger features.
Enables the selection of a trigger source that starts
the Acquisition of one or many frames.
Controls the enable state of the selected trigger.
Off
The selected trigger is turned off.
On
The selected trigger is turned active.
Sets the total number of frames to acquire when a
valid trigger is received. This feature is available
when Trigger Selector = MultiFrame Trigger(Start).
Generate a software command internal trigger
immediately no matter what the TriggerSource
feature is set to.
Specifies the internal signal or physical input line to
use as the trigger source. The selected trigger must
have its TriggerMode set to ON.
See Input Signal Electrical Specifications.
Line0
Select Line 0 (and associated I/O control block) to
use as the external trigger source. See LineSelector
feature for complete list.
View
Beginner
Beginner
DFNC
Beginner
Beginner
Beginner
Operational Reference • 65