Cc0x73PowerLevel
Cc0x81Clock
Cc0x84WakeUp
Cc0x85Association
Cc0x87Indicator
The GUI representation column defines how command classes are seen in the eZLO apps' GUI. Some of
them are not available in the UI and cannot be managed through the app; however, you can see the
information provided by these commands. For example, you can't manage a motion sensor, but you can
see the data on motion tracked by this device. The values of such devices can only be managed through
the device itself. For instance, opening and closing the door changes the status of the door sensor, and
the remote control requires a physical pressing of its buttons to operate it.
Other command classes allow managing devices both through the eZLO's UI and the devices
themselves. Each such device has a visual control panel in the eZLO app (which appears after the device
was included to the Z-Wave network and placed to any room in the eZLO app).
The eZLO Hub can receive, interpret and display to the user various kinds of reports. These include
reports implemented in different Command Classes as well as Notification Command Class messages.
Replication and Backup
Replication​ is the process of creating an image of an eZLO containing a list of connected slave devices
along with the eZLO itself and their settings. Replica images are created automatically. A user can only
copy a replica image to another selected eZLO.
Note:​ A replica can be restored only to eZLOs different from the one which was replicated.
Backup​ is a process of creating an image of an eZLO containing a list of connected slave devices and
settings of these devices and the eZLO itself. A user can create backups manually and can use backup
images to restore the previously saved state of the same eZLO that was previously backed up.
Note:​ A backup image cannot be used on an eZLO different from the one it was made of."
Not used in
Pushes the powerlevel
UI
test with powerlevel
Not used in
Sets the clock time of
UI
the device (the
controller's time)
Not used in
Sets the wakeup time
UI
for sleeping device
(fixed interval)
Button with
Sets the association to
group add /
group or removes
remove (2
association from group
groups only)
Not used in
Sets the indicator
UI
state, but not used at
the moment
powerlevel_
test
clock
wakeup
association
indicator
65
Automatic
interview
Automatic
interview
Automatic
interview
Automatic
interview
Automatic
interview