Control Board connection for the rear handle bar
membrane switch controls is as follows:
• J9, Control Board right connector receptacle.
• Large white connector (circled) with multiple
white and yellow wires to J9 Control Board right
receptacle .
• Multiple white and yellow wires from Control
Board to J4 on the rear connection panel board
(circled at the bottom of image to the left) .
• Rear connection panel. Left is for display power
and communications, center is an RJ45 network
type cable for the rear handlebar membrane
switch controls and right is the Pro Stitcher pass
through 24V power to the front Pro Stitcher black
box for tablet power and Pro Stitcher carriage mo-
tor RS232 communications.