Setting-Up With Remote Unit S - Satron Instruments SATRON VC Installation And Setting-Up Instructions

Optical consistency transmitter
Table of Contents

Advertisement

SATRON VC Optical Consistency Transmitter
2.3
Setting-up with remote unit.
The Satron VC transmitter remote unit can be provided with a wall box which is capable of having a 20m cable
between the Sensing unit and the Display unit. Inside the Display unit is a terminal where up to 3 binary inputs, 3 relay
outputs and 2 analog milliamp loops can be connected. All connections can be used simultaneously.
The signal cable between the Display unit and Sensing unit should not be installed near high-voltage cables, large
motors or frequency converters.
Figure 2 - 3 Remote Connections
Figure 2 - 4 VC Sensing connections.
Inside the Sensing element is a dipswitch and a USB port. This is only used for updating the fi rmware.
DO NOT USE THE USB PORT UNLESS THERE NEEDS TO BE A NEW FIRMWARE INSTALLED.
9
BCs220AV
Revision 2
15.10.2014