C. Settings and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the "E" and "G"
control boards:
a) "E" and "G" Control Board without Harvest Pump Timer Operation
Auxiliary
Model
Code
KM-1601SWH/3
KM-1601SRH/3
R-0, R-1,
some S-1
Some S-1
S-2 & later
V-1 (M) & later
KM-1900SAH/3
KM-1900SWH/3
KM-2100SWH3
KMH-2000SWH/3
KMH-2000SRH3
KM-1900SRH/3
KM-2100SRH3
KM-2500S_H3
KMH-2000SRH
NOTICE
Code on
Water Valve
Water
Part Number
Valve
All
3U0111-02
J248-032
(8 l/min)
3U0111-01
J248-030
(15 l/min)
4A1176-04 (11 l/min)
4A5251-04 (11 l/min)
All
All
All
All
51
S4 Dip Switch No.
1
2
3
4
5
OFF OFF OFF OFF ON ON OFF OFF OFF ON
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
ON OFF OFF OFF ON ON OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
ON OFF ON ON OFF OFF OFF OFF ON OFF
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
OFF OFF OFF OFF OFF OFF OFF OFF ON ON
6
7
8
9
10