B) "G" Control Board With Harvest Pump Timer Operation; C) "G" Control Board S5 Dip Switch; Harvest Timer (S4 Dip Switch 1 & 2) - Hoshizaki KM-1301SAH/3 Service Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1301SAH/3:
Table of Contents

Advertisement

b) "G" Control Board with Harvest Pump Timer Operation

S4 Dip Switch No.
KM-1301SAH/3
KM-1301SWH/3
KM-1601SAH/3
KM-1301SRH/3
KM-1400SWH-M
KM-1400SWH3-M

c) "G" Control Board S5 Dip Switch

S5 Dip Switch (Do Not Adjust)
S5 Dip Switch No. 1
All
S4 Dip Switch
"E" and "G" Control Boards
Factory Use (8)
Bin Control Selector (7) "E" Control Board
Harvest Pump Timer (7) "G" Control Board
(Do Not Adjust)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
2. Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reaches 48°F (9°C) at the
evaporator outlet and the control board reads 3.9 kΩ from the thermistor. The harvest
timer is factory set, and generally no adjustment is required. However, a setting longer
than the factory setting may be advised in cases where the drain provided at harvest
needs to be prolonged for extra cleaning. Note that the pump-out timer (S4 dip switch
3 & 4) acts in place of the harvest timer during cycles with a pump out. For details, see
"III.C.3. Pump-Out Timer (S4 dip switch 3 & 4)."
Note: On models with a pump-out every cycle, the harvest timer is only relevant during
the initial harvest cycle since a pump out occurs every cycle thereafter.
S4 Dip Switch
1
2
3
4
OFF OFF ON ON ON ON ON OFF OFF OFF
OFF OFF ON ON ON ON ON OFF ON OFF
OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
2
3
4
5
OFF OFF OFF OFF OFF
Freeze Timer (9 & 10)
S4 Dip Switch Setting
No. 1
OFF
ON
OFF
ON
5
6
7
8
9
Time
(sec.)
No. 2
OFF
60
OFF
90
ON
120
ON
180
52
10
S5 Dip Switch
"G" Control Board
Refill Counter (2 through 5)
Float Switch Selector (1)