T r o u b l e s h o o t i n g
Faults
Possible cause
Engine over-
Cooling air inlets excessively soiled
heating, engine
Engine oil level too low
must be shut
down immedi-
Lack of cooling air on cooling fan
ately!
Air filter dirty
Too low engine
Leaks in the lubrication oil system, engine
oil pressure, en-
oil level too low
gine must be
shut down im-
mediately!
Engine oil of wrong SAE-class
7 0
Remedy
clean
Fill up engine oil to the top dipstick mark
Clear the cooling air duct
clean, replace if necessary
Check fittings on oil lines, lubrication oil fil-
ter for leaks, if necessary tighten all fit-
tings. Fill up lubrication oil to the top mark
on the oil dipstick.
Change engine oil