Access Local Ui Using Remote Access; Update The Moip Controller Firmware; Power Off The Moip Switch, Then Connect Devices; Powering Up The System - Binary B-900-MOIP-4K-CTRL Installation & Setup Manual

Media over ip system
Hide thumbs Also See for B-900-MOIP-4K-CTRL:
Table of Contents

Advertisement

2. New OvrC locations
a. Document the MoIP Controller MAC Address and Service Tag on the box or on the
bottom of the device
b. Log into OvrC and go to Customer > Devices, click "+ Device"
c. Manually enter MAC Address and Service Tag to claim the device

5. Access Local UI using Remote Access

Connect the controller to the MoIP Switch, then use the external power supply to connect to
an AC outlet.
1. Once connected, log into the MoIP Controller (username/pasword is binary/binary). You
can change the user name and password under the
recommended to apply a static IP
2. It is
click Enable. Apply a static address to the MoIP controller on the same ip address range.
Click
Save
to apply.

6. Update the MoIP Controller Firmware

Available firmware updates are visible in the
provided in OvrC to complete.

7. Power off the MoIP Switch, then Connect Devices

1. Connect sources via HDMI to the MoIP Transmitters.
2. Connect displays or A/V receivers via HDMI to the MoIP Receivers.
3. The transmitter and receiver are PoE powered (no power supply is included).
4. The controller must be powered by the included external power supply.

8. Powering Up the System

1. Turn on all displays, sources and other related A/V equipment
2. Verify the MoIP Controller is also powered up.
3. Apply power to the MoIP Switch. This will supply power on all connected MoIP devices.
Configure> Account
address. Navigate to the
Device List
for that location in OvrC. Follow steps
11
Management.
Configure >IP Settings
and

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-900-moip-4k-txB-900-moip-4k-rx

Table of Contents