ANDERSON-NEGELE ITM-51 Operating Manual

ANDERSON-NEGELE ITM-51 Operating Manual

Relative turbidity meter
Hide thumbs Also See for ITM-51:

Advertisement

SENSORS FOR FOOD AND LIFESCIENCE.
Operating Manual
Relative Turbidity Meter
ITM-51 / ITM-51R
ITM-51/ITM-51R
30022 /1.1 / 2018-07-16 /TB / EU

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITM-51 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ANDERSON-NEGELE ITM-51

  • Page 1 SENSORS FOR FOOD AND LIFESCIENCE. Operating Manual Relative Turbidity Meter ITM-51 / ITM-51R ITM-51/ITM-51R 30022 /1.1 / 2018-07-16 /TB / EU...
  • Page 2: Table Of Contents

    Operating Manual ITM-51/ITM-51R Table of contents Table of contents ....................2 Application / intended use ................. 3 Conformity with standards ................ 3 Safety instructions ..................3 Special features / advantages ..............4 Options / accesories .................. 4 Installation and connection ................ 4 Mounting position ....................
  • Page 3: Application / Intended Use

    Operating Manual ITM-51/ITM-51R Application / intended use • Relative turbidity measurement of liquid media for mid to high turbidity range (200…300.000 NTU equivalent) • For use in hygienic applications of the food, beverage and pharmaceutical industries • Suitable for CIP/ SIP up to 140°C for a maximum of 120minutes •...
  • Page 4: Special Features / Advantages

    Operating Manual ITM-51/ITM-51R Special features / advantages • The sensor structure is based on a modular device platform which can be tailored to requirements and is easy to exchange if faulty • Front flush sensor for easy cleanability • Optics made of high resistance sapphire •...
  • Page 5: Hygienic Installation Requirements

    Operating Manual ITM-51/ITM-51R Hygienic installation requirements Conditions for hygienic installation according 3A and EHEDG • The ITM-51 / ITM-51R is designed for CIP/SIP cleaning. The sensor can withstand a maxi- mum of 140°C/120min. • The mounting position must guarantee self-draining properties •...
  • Page 6: Parameterisation

    X45a and for output 2 (terminals 6 and 7) under X67. The ITM-51 relative turbidity meter features a modular design with a “tree structure”, which can be tailored to meet requirements and can be easily exchanged in the event of a fault.
  • Page 7: Settings Using The Mpi-200 Programming Adapter

    7.1 Settings using the MPI-200 programming adapter The MPI-200 programming adapter is connected to the ITM-51 turbidity meter via the external MPI-200-F adapter piece. It must be ensured that the ITM-51 turbidity meter is permanently connected to the supply voltage while the parameters are being set.
  • Page 8 Operating Manual ITM-51/ITM-51R 1. Information on the current process value 2. Buttons for changing the parameter setting 3. Information on the current source value 4. Adjustable PC parameters 5. Adjustable sensor parameters Clicking on the + in the menu opens a submenu in which parameters can be adjusted.
  • Page 9 Operating Manual ITM-51/ITM-51R List of important ID codes: Search Number Parameter/Parameter Name Access/Setup Mode Value Name (ID Number) Sensor Unit Turb1 Setup 014021 Turbidity1 Damping 1 Setup 014027 Turbidity1 Range Tb.1 Setup 014029 Turbidity1 Unit Turb1 Setup 014022 Turbidity2 Damping 1...
  • Page 10 Operating Manual ITM-51/ITM-51R Direction Setup 330821 Digital-In Simul. Inp Setup 330831 Digital-In Current Loop Signal 2 Signal Selection Setup 330032 X45b I-Out Underrange Limit Setup 330142 X45b I-Out Overrange Limit Setup 330212 X45b I-Out no Media= Setup 330122 X45b I-Out Out Spec.=...
  • Page 11: Settings Using The User Interface

    Operating Manual ITM-51/ITM-51R Simulation Setup 331244 X67 D-Out Display Language Setup 451010 Set Display Contrast Setup 451020 Set Display Scrs delay Setup 451050 Set Display Password Setup 450103 Set Display 7.2 Settings using the User Interface The software structure of the User Interface is similar to that of the PC version.
  • Page 12: Led Configuration

    Operating Manual ITM-51/ITM-51R 7.2.2 LED configuration The display unit features 2 LEDs that can be individually configured. The LED to the left of the display is LED 1 while the one to the right is LED 2. The following options can be selected when setting the LEDs: •...
  • Page 13: Menu Structure User Interface

    Operating Manual ITM-51/ITM-51R 7.3.1 Menu structure User Interface In the following flow-chart the parameter setup of the second level is shown. Menu Menu Menu Menu Menu QuickSetup QuickSetup QuickSetup QuickSetup QuickSetup Setup Setup Setup Setup Setup ID Search ID Search...
  • Page 14: Example For Setting Turbidity 1 Range Without An Id Code

    Operating Manual ITM-51/ITM-51R 7.3.2 Example for setting turbidity 1 range without an ID code: Menu Quick Setup Turbidity 1 R la. x.xx %TU Save Data? QuickSetup Unit Turb1 ID: 014030 Setup Unit Turb2 Range Tb.1 No / Yes ID Search Range Tb.1...
  • Page 15: Setting Of Customer-Specific Turbidity / %Solids Curve Via Pc Software

    Operating Manual ITM-51/ITM-51R 7.3.3 Setting of customer-specific turbidity / %solids curve via PC software: After the PC software is started, a customer-specific curve for the turbidity can be entered via the following node: Turbidity Measurement  % solids  (+). Values need to be entered for at least 2 X and Y points. Up to 8 support points for X and the associated Y values can be entered to establish the relationship between turbidity (X) and % solids (Y).
  • Page 16: Installation Of The „Large User Interface" (Lui)

    Operating Manual ITM-51/ITM-51R Installation of the „Large User Interface“ (LUI) Remove the plastic cover (continue with step 4), or remove the puck with the mounted small display (con- tinue with step 2) Remove the small display Install the puck in the sensor head...
  • Page 17: Retrofitting The Display If A Small Display (Sui) Was Already Installed

    Operating Manual ITM-51/ITM-51R 8.2 Retrofitting the display if a small display (SUI) was already installed First the puck with the mounted display needs to be removed using the puck puller tool (Fig. 1). To do so, detach the wires from the cable terminal. Then insert the five arms of the puck puller in the plastic tabs of the puck (Fig. 2).
  • Page 18: Dimensions

    Operating Manual ITM-51/ITM-51R Dimensions ITM-51 with vertical head orientation. Process Connection TriClamp size Varivent size Type Ø A Type Ø A Ø B TC1 / TL1 50,5 mm 66,00 mm 57,00 mm TC2 / TL2 64,00 mm 84,00 mm 75,00 mm...
  • Page 19: Wiring Diagram

    Operating Manual ITM-51/ITM-51R ITM-51 with horizontal head orientation. Process connection Wiring diagram Electrical connection with M12-connector Version N (Electronic A53) M12 connector top (4 pin) out 1+ out - / D out out + / D out out 1- M12 connector bottom (5 pin)
  • Page 20 Operating Manual ITM-51/ITM-51R Version M (Electronic A42) M12 Stecker oben (4 pin) power supply +24 VDC out + out - power supply - Version A (Electronic A53) M12 connector top (4 pin) out - out + power supply +24 VDC...
  • Page 21: Repair And Maintenace

    5. Checking the displayed NTU value and compare with the reference value printed on the label of ITM- 51-CU. The value needs to be within the range of ±6% as printed on the label as well. 6. If the displayed value is outside the limits it is recommended to send back the ITM-51 for recalibra- tion.
  • Page 22: Technical Data

    Operating Manual ITM-51/ITM-51R Technical data Measurement category The measurement category %TU, NTU, EBC, %solids (customized) can be selected Measurement range The measurement range is 0…300.000 NTU equivalent freely adjustable 0…200 %TU 0…75.000 EBC Process connection CLEANadapt G1/2" hygienic TriClamp 1.5", 2", 2.5", 3"...
  • Page 23 Operating Manual ITM-51/ITM-51R Output 1 analog outputs 4...20 mA (scaled to measurement range) 1 switching output potential free switching output Weight 750 g...
  • Page 24 Operating Manual ITM-51/ITM-51R Negele Messtechnik GmbH | Raiffeisenweg 7 | 87743 Egg an der Guenz | Germany | Phone: +49 (0) 83 33 . 92 04 – 0 | Fax: +49 (0) 83 33 . 92 04 - 49 Anderson Instrument Company Inc. | 156 Auriesville Road | Fultonville, NY 12072 | Phone: 518-922-5315 | Fax: 518-922-8997...

This manual is also suitable for:

Itm-51r

Table of Contents