User Manual Blood Pressure Monitor TMB-1014-BT Wrist Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1014-BT. Zhongshan Transtek Electronics Co., Ltd To use the monitor correctly and safely, please read the manual Jin’an Road, Minzhong, Zhongshan 528441, Guangdong, China thoroughly.
The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable Reading taken by the TMB-1014-BT are equivalent to those obtained by a trained anesthetic mixture with air of with oxygen or nitrous oxide.
INTRODUCTION INTRODUCTION LCD display signal Monitor components MEM/UP SYSTOLIC BUTTON GRADE DIASTOLIC START/OFF BUTTON PULSE RATE LCD DISPLAY TIME SET/DOWN BUTTON Systolic High pressure result blood pressure Diastolic Low pressure result blood pressure Pulse Pulse/minute CUFF Low battery Batteries are low and need to be replaced (Type B applied part) mmHg Measurement unit the blood pressure...
BEFORE YOU START BEFORE YOU START The installment and replacement of battery Setting Date, time and measurement unit Slide off the battery cover. It is important to set the clock before using your blood pressure Install the batteries by matching the correct polarity, as shown monitor, so that a time stamp can be assigned to each record that below is stored in the memory.
Page 5
BEFORE YOU START BEFORE YOU START Bluetooth phones’ test software 4.Repeat the 2 and 3 to .Open the Bluetooth 4.0 special test set the [Minute]. mobile phones after electrify blood pressure monitor. .After operating Bluetooth Test program (It is about 8 m from mobile to blood pressure monitor), the “discovered device”...
BEFORE YOU START MEASUREMENT Positioning the wrist cuff .When the blood pressure monitor show “[ ]”, it means matching successfully; .Remove all accessories (watch, bracelet, etc) from your left wrist. If your W h e n i t d i s p l a y ” E 1 ” , i t i n d i c a t e s physician has diagnosed you with poor circulation in your left wrist, use your matching unsuccessfully.
Page 7
MEASUREMENT MEASUREMENT Start the Measurement Please press the SET to choose the user 1 or user 2 when the blood pressure monitor 2.A f te r me as u rin g, turn off i t’ ll d is pl ay t he mo v in g “o”...
THE OPERATION OF THE OPERATION OF RECALLING RECORDS RECALLING RECORDS Recalling the records Deleting a measurement record from memory If you did not get the correct measurement, you can delete all 1.Press the “MEM” to show results by following below steps. the last 3 average of the record.
INFORMATION FOR USER INFORMATION Tips for measurement Maintenance It can cause incorrectness if the measurement are taken in the In order to get the best performance, please follow the below following circumstances. instructions. Avoid touching water, Wait at least 1 hour Immediate measurement Put in a dry place and avoid the sunshine clean it with a dry cloth in case.
ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic Why my blood pressure is varies even in one pressure? Systolic Diastolic day? When ventricles contract and pump blood blood entering blood discharging out of the heart, blood pressure reaches its 1.
SPECIFICATIONS TROUBLESHOOTING This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood Power supply 2*AAA alkaline batteries pressure monitor. If the products not operating as you think it should, check here before arranging for servicing. Display moder Digital LCD V.A.36x41mm Measurement mode...
5) Each frequency or frequency band of reception; the preferred frequency or frequency band, if applicable, and the bandwidth of the receiving section of the ME EQUIPMENT or ME SYSTEM in those bands; 6) Warning: the TMB-1014-BT may be interfered with by other equipment, even if that other equipment complies with CISPR EMISSION requirements.
Page 13
Table 4 Guidance and manufacture’s declaration – electromagnetic immunity – Table 2 Guidance and manufacture’s declaration – electromagnetic immunity – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration – electromagnetic immunity Guidance and manufacture’s declaration –...
Page 14
Table 6 Recommended separation distances between portable and mobile NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. RF communications equipment and the EQUIPMENT or SYSTEM – NOTE 2 These guidelines may not apply in all situations. Electromagnetic for ME EQUIPMENT or ME SYSTEM that are not LIFE-SUPPORTING propagation is affected by absorption and reflection from structures, objects and people.
Page 15
This device complies with Part 15 and Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.