ESIE15-08B
|
Part 3. Repair

2. Unit specific repair procedures Monobloc CA

C
AUTION
If the platework of the
platework no longer aligns correctly with the hea

2.1. Unit specific refrigerant and water procedures

Overview of parts replacement procedures:

Removing the hydrobox top plate assembly................................. 110

Removing the hydrobox front plate............................................... 111
Removing the top plate................................................................. 112

2.1.1. Removing the hydrobox top plate assembly

1.
Switch off the Daikin Altherma Monobloc CA via the user interface.
2.
Switch off the Daikin Altherma Monobloc CA with the field supplied circuit breaker.
3.
Loosen and remove the 3 screws (1) that fixe the hydrobox top plate (2) to the hydrobox.
4.
Lift the hydrobox top plate assembly (2) and remove it from the hydrobox.
1
1. Screw
Page 110
Daikin Altherma Monobloc CA
Daikin Altherma Monobloc CA is bent (e.g. when replacing a thermistor), chances are the
Figure 5 - Removing the hydrobox top plate assembly
1
2
2
2. Unit specific repair procedures Monobloc CA
t exchanger. This will increase the risk of ice build-up.
Removing the front plate assembly .............................................. 113
Removing the compressor sound insulation................................. 115
1
2
1
2. Hydrobox top plate assembly
2
19/07/16