Graco EnDure Instruction Manual page 8

Automatic dispense valves
Hide thumbs Also See for EnDure:
Table of Contents

Advertisement

Installation
Connect Air Lines to Dispense Valve
CAUTION
Only use air fittings that are rated at a temperature
equal to or higher than the operating temperature
of your fluid dispensing system. Lower rated air
fittings could melt and cause damage to the
automatic dispense valve.
These valves are air to open and air to close with a
spring to bias them closed. Use a 4-way exhausting
solenoid to operate these valves.
Be sure to connect the appropriate air lines to the
appropriate ports (Fig. 2), and securely connect air lines
to dispense valve air ports. See page 32.
240 volt heated model shown
Fig. 2 ______________________________________________________________________________________
8
Open and Close
ports are on this
side.
Connect Material Hose to Dispense Valve
Securely connect the material hose to the dispense
valve material inlet port. See Fig. 2.
Connect Electrical Cable to Electrically
Heated Dispense Valves
Connect electrical cable plug from your Therm-O-Flow,
Therm-O-Flow Plus, or PrecisionFlo hose or control.
A six-pin round connector is used on 120 volt valves and
an eight-pin square connector is used on 240 volt
valves.
Fluid Inlet
Temperature
insulation
spacer
309376L