Baxi iMPI/E V200 4-8 User Manual page 27

Impi v200 series reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

Parameter
Description
CP082
User Room Setpoint Zone Activity temperature in activity zone 3
Can be set from 5 °C to 30 °C
CP083
User Room Setpoint Zone Activity temperature in activity zone 4
Can be set from 5 °C to 30 °C
CP084
User Room Setpoint Zone Activity temperature in activity zone 5
Can be set from 5 °C to 30 °C
CP085
User Room Setpoint Zone Activity temperature in activity zone 6
Can be set from 5 °C to 30 °C
CP140
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 1
Can be set from 20 °C to 30 °C
CP141
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 2
Can be set from 20 °C to 30 °C
CP142
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 3
Can be set from 20 °C to 30 °C
CP143
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 4
Can be set from 20 °C to 30 °C
CP144
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 5
Can be set from 20 °C to 30 °C
CP145
Setpoint of the Room Cooling Temperature of the zone: cooling ac­
tivity zone 6
Can be set from 20 °C to 30 °C
CP200
Manually setting the RoomTemperature setpoint of the zone
Can be set from 5 °C to 30 °C
CP320
Operating mode of the zone
0 = timer programming
1 = manual mode
2 = frost protection mode
CP350
Comfort Domestic Hot Water Temperature Setpoint of zone
Can be set from 40 °C to 80 °C
CP360
Reduced Domestic Hot Water Temperature Setpoint of zone
Can be set from 10 °C to 60 °C
CP510
Temporary room setpoint per zone
Can be set from 5 °C to 30 °C
CP540
Setpoint of swimming pool when Zone is configured on
SwimmingPool
Can be set from 0 °C to 39 °C
CP550
Fire Place mode is active
0 = off
1 = on
7700954 - v03 - 13082018
Factory setting
Factory setting
CIRCA
CIRCB
6
6
21
21
22
22
23
20
30
30
25
25
25
25
25
25
25
25
25
25
20
20
0
0
not available
55
not available
10
20
20
not available
20
0
0
iMPI V200
6 Settings
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impi/e v200 11-16Impi/h v200 4-8Impi/h v200 11-16

Table of Contents