Panel mounting (optional)
Torque each panel clamp anchor screw to 0.5 to 0.6 Nm (4.42
to 5.31 lbf/in.)
IMPORTANT (NOTE)
Do not overtighten the screws.
Dimensions in mm (in.)
Mounting panel –
maximum thickness
6 (0.236)
 40 (1.57)**
Panel cut-out dimensions*
* To DIN43700
**150 mm (6 in.) if (optional) cable glands fitted
CI/AWT440–EN Rev. A
35
92
(1.4)
(3.6)
Cable gland kit
(optional)
Panel-mount kit
+1.1
186
–0
+0.04
(7.32
)
–0
+1.1
186
–0
+0.04
(7.32
–0
 40
(1.57)
Pipe mounting (optional)
Dimensions in mm (in.)
194
(7.64)
Pipe diameters:
max. 62 (2.44) / min. 45 (1.77)
)
Vertical
configuration
213 (8.38)
EZLink
Cable gland kit
connectors
(optional)
98 (3.85)
66 (2.6)
Pipe-mount kit
Horizontal
configuration