Display icons

Alarm, hold, clean and calibration icons
Alarm – indicates a user-defined alarm condition
(20-character) and flashes intermittently with an
associated NAMUR diagnostic icon.
Hold – indicates that alarms / analog outputs are in
a manual hold state.
Calibrating – indicates that a calibration is in
progress.
Cleaning – indicates that a manual or automatic
clean is in progress.
Title bar icons
Log mode – indicates that one of the View pages is
currently displayed (Calibration, Alarm, Audit or
Diagnostic).
View mode – indicates that one of the View pages is
currently displayed (Diagnostics, Alarms, Outputs,
Signals or Chart).
Media on-line: 0 to <20 % full.
Media on-line: 20 to <40 % full.
Media on-line: 40 to <60 % full.
Media on-line: 60 to <80 % full.
Media on-line: 80 to <100 % full.
Media on-line: full (icon toggles when full).
Media off-line: 0 to <20 % full.
Media off-line: 20 to <40 % full.
Media off-line: 40 to <60 % full.
Media off-line: 60 to <80 % full.
Media off-line: 80 to <100 % full.
Media off-line: not inserted (not logging).
Media off-line: not inserted, logging active
– icon display toggles with Media off-line: not
inserted (not logging) icon.
CI/AWT440–EN Rev. A
Status bar icons
Operator menu – displays the Operator menu when
the
key is pressed.
Autoscroll – indicates that Operator pages are
displayed sequentially. Displayed only when
Autoscroll enabled from the Operator menu.
Disabled if 1 Operator page only is configured for
display.
Calibration – shortcut access to the Calibration
page when the
Enter – selects the highlighted option from the
Operator menus when the
Service Level – indicates that alarms and analog
outputs are held.
Advanced Level – indicates that Advanced Level
parameters are enabled for the current user.
Calibrate Level – indicates that the Calibration Level
parameters are enabled for the current user.
Read Only Level – indicates that the transmitter is in
Read Only mode. All parameters are locked and
cannot be configured.
Cleaning – indicates that a manual or automatic
clean is in progress.
In Hold Mode – indicates that alarms / analog
outputs are in a manual hold state.
High process alarm active / inactive.
Low process alarm – active / inactive.
High latch alarm – active / inactive.
Low latch alarm – active / inactive.
key is pressed.
key is pressed.