Ningbo Ginlong Technologies Solis-20K Installation And Operation Manual page 25

Pv grid tie inverter, solis three phase inverter
Table of Contents

Advertisement

10. Specification
Model
The max DC input power
The max DC input voltage
Starting-up input voltage
MPPT operation range
Max dc input current
Number of MPPT/strings per MPPT
Rated output power
Rated grid voltage
The grid voltage range
Operation phase
Rated grid output current
Output power factor
Grid current THD
The dc injection current
Rated grid frequency
Max. Efficiency
Protection
Size(mm)
Weight
Topology
Internal consumption
Operating temperature
Ingress protection
Interface
Design lifetime
Operating Range Utility Frequency
Utility Monitoring
Operation Surroundings Humidity
EMC
.46.
Solis-30K
34kW
1000V
350V
200~800V
18+18+18+18Adc
4/8
30kW
380V
304~460Vac(adjustable)
Three phase
43.3A
>0.99
<3%
<50mA
50/60Hz
98.5%
DC reverse-polarity; AC short circuit protection;
Islanding protection; temperature protection;Lightning protection
530W*700H*356.5D
58.2kg
Transformerless
<1W(Night)
-25~60℃
IP65
Rs485 WIFI GPRS(Optional)
>20years
47-52 or 57-62Hz
Islanding protection, VA C FA C in accordance with UL 1741,
G59/3, AS4777, VDE 0126-1-1, VDE 4105, CEI 0-21, CQC
0~95%
EN61000-6-1:2007
EN61000-6-3:2007
Model
The max DC input power
The max DC input voltage
Starting-up input voltage
MPPT operation range
Max dc input current
Number of MPPT/strings per MPPT
Rated output power
Rated grid voltage
The grid voltage range
Operation phase
Rated grid output current
Output power factor
Grid current THD
The dc injection current
Rated grid frequency
Max. Efficiency
Protection
Islanding protection; temperature protection;Lightning protection
Size(mm)
Weight
Topology
Internal consumption
Operating temperature
Ingress protection
Interface
Design lifetime
Operating Range Utility Frequency
Utility Monitoring
Operation Surroundings Humidity
EMC
10. Specification
Solis-30K-HE
34kW
1000V
600V
575~850V
52.2Adc
1/8
30kW
380V
304~460Vac(adjustable)
Three phase
43.3A
>0.99
<3%
<50mA
50/60Hz
99.0%
DC reverse-polarity; AC short circuit protection;
530W*700H*356.5D
50kg
Transformerless
<1W(Night)
-25~60℃
IP65
Rs485 WIFI GPRS(Optional)
>20years
47-52 or 57-62Hz
Islanding protection, VA C FA C in accordance with UL 1741,
G59/3, AS4777, VDE 0126-1-1, VDE 4105, CEI 0-21, CQC
0~95%
EN61000-6-1:2007
EN61000-6-3:2007
.
47
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solis-25kSolis-30kSolis-36k-hvSolis-40k-hvSolis-30k-he

Table of Contents