Yamaha L2 Command Reference Manual page 61

Intelligent l2 poe swr2311p-10g
Table of Contents

Advertisement

rmon alarm index variable interval interval [type] falling-threshold falling_threshold event falling_event_index
[owner owner]
no rmon alarm index
[Parameter]
index
:
<1-65535>
Index of alarm group (alarmIndex)
variable
:
MIB object to be monitored (alarmVariable)
interval
:
<1-2147483647>
Sampling interval (seconds)(alarmInterval)
type
:
Sampling type (alarmSampleType)
absolute
delta
(if omitted : absolute)
rising_threshold
:
<1-2147483647>
Upper threshold value (alarmRisingThreshold)
rising_event_index :
<1-65535>
Event index (alarmRisingEventIndex)
falling_threshold
:
<1-2147483647>
Lower threshold value (alarmFallingThreshold)
falling_event_inde
:
<1-65535>
x
Event index (alarmFallingEventIndex)
startup
:
<1-3>
Threshold value used for first alarm decision (alarmStartupAlarm)
1
2
3
(if omitted : 3)
owner
:
Name of alarm group owner (alarmOwner)
maximum 127 characters
(if omitted : RMON_SNMP)
[Initial value]
none
[Input mode]
global configuration mode
[Description]
Enables the RMON alarm group settings.
Command Reference | Maintenance and operation functions | 61
Setting value
Setting value
Description
Compare by absolute value. Directly compare
sample value and threshold value
Compare by relative value. Compare the
difference between the latest sample value and
the previous sample value
Description
Use only upper threshold value (risingAlarm)
Use only lower threshold value (fallingAlarm)
Use both upper threshold value and lower
threshold value (risingOrFallingAlarm)