WS-AP3660 Power Supply Installation Procedures

Ground Connection

1.
The ground connection for the WS-AP3660 is located on the rear of the device. Attach a
ground to earth cable to one of two grounding terminals using one ground screw (see
Figure
Figure 2-8
1

Power Connections

The WS-AP3660 can be powered in one of the following ways:
Power over Ethernet (PoE)
Power is provided to the LAN port of the WS-AP3660 with a PoE injector. The PoE injector
must be 802.3at compliant and is not provided with the WS-AP3660.
Power by external power supply
An external 12VDC power supply (WS-PS3660-MR) can be purchased to power the
WS-AP3660. For more information on the installation process, see
Installation Procedures
WS-AP3660 Power Supply Installation Procedures
These procedures describe how to attach the mounting bracket to the WS-AP3660 Power Supply,
how to mount the power supply outside (either a wall or pole), and how to attach the relevant
cables.
2-8).

WS-AP3660 Grounding Terminals

Grounding terminals (2)
Note: The RJ45 connector used for providing PoE to the WS-AP3660 must be contained within a
waterproof adapter assembly before being installed. For more information, see
Connections (with Cable Gland Adapter
below.
Electrical Hazard: This product should be installed and serviced by a qualified licensed technician,
electrician, or electrical maintenance person familiar with its operation and the hazards involved.
Assembly)" on page 2-8.
Enterasys Wireless Outdoor WS-AP3660 Installation Guide 2-11