3 Technical Data

Admissible operating conditions
Mains voltage:
The mains voltage must comply with the mains voltage indicated on the type
plate.
Speed ranges:
Admissible ambient temperature:
The maximum ambient temperature specified on the type plate must not be
exceeded.
IMPORTANT
These values are valid for operation with an ON-period of 100 %.
Cycled or frequency-controlled operation or synchronous operation are sub-
ject to specific requirements. These must be clarified with NetterVibration for
each individual case.
These electric vibrators must not be used in environments with an explosive
gas atmosphere.
Sound level:
*) Higher temperatures are only possible after consultation of and written approval from the application
technicians of Netter GmbH.
Series NED: direct current 12 V or 24 V
Direct current 3000 rpm or 3600 rpm
-20 °C to 40 °C*
Depending on type ≤ 70 dB(A)
The sound level is determined to a great extent by the surface upon
which the vibrator is mounted (e.g. sheet metal). The sound level will be
amplified by non-silenced sheet metal.