NetterVibration NED 605 Operating Instructions Manual

NetterVibration NED 605 Operating Instructions Manual

Series ned electric external vibrator
Hide thumbs Also See for NED 605:

Advertisement

These operating instructions apply to:
Operating Instructions for
Netter Electric External Vibrators
Series NED
Dec. 2017
No. 989E
Page 1/20

Advertisement

Table of Contents
loading

Summary of Contents for NetterVibration NED 605

  • Page 1 Operating Instructions for Dec. 2017 Netter Electric External Vibrators No. 989E Page 1/20 These operating instructions apply to: Series NED...
  • Page 2: Table Of Contents

    Table of Contents GENERAL NOTES SAFETY TECHNICAL DATA DESIGN AND FUNCTION TRANSPORT AND STORAGE INSTALLATION Fastening of the vibrator Electrical connection START-UP ADJUSTMENT OF UNBALANCES TROUBLE SHOOTING SERVICE / MAINTENANCE SPARE PARTS ACCESSORIES DISPOSAL Scope of delivery As a rule, the NEG are delivered with the Check the packaging for possible signs of following components: transport damage.
  • Page 3: General Notes

    Installation, commissioning, maintenance, Translations made best fault elimination and disassembly of the NetterVibration knowledge. does NED must only be performed by persons assume any liability for translation errors, who have been instructed in the proper even if the translation was made by us or handling of the units.
  • Page 4 The following instruction and warning symbols are used in this operating manual: indicates a possible danger which will result in DANGER death or personal injury if the instruction is not followed. indicates a possible risk which can result in WARNING personal injury and/or material damage if the instruction is not followed.
  • Page 5 In particular, the standards DIN EN ISO 12100, EN 60529 and DIN EN 60034-1 have been complied with. Special features: • Adjustable centrifugal force, NED 605 have a fixed unbalance • 100 % duty cycle • Minimum protection type IP 66 •...
  • Page 6: Safety

    2 Safety Intended use: Qualification of the personnel: The vibrators are intended for installation in Assembly, commissioning, maintenance machines according to the device group and repair of the vibrators must be and the device category. These machines performed only by authorised qualified use vibrations for sieving, loosening, con- personnel.
  • Page 7: Technical Data

    These values are valid for operation with an ON-period of 100 %. Cycled or frequency-controlled operation or synchronous operation are sub- ject to specific requirements. These must be clarified with NetterVibration for each individual case. These electric vibrators must not be used in environments with an explosive gas atmosphere.
  • Page 8 Size/ type unbalance [cmkg] [kW] [kg] minute material discs NED 605 24 ( - ) 0,07 0,011 0,45 3.600 - / AL / POM NED 5016 24 (12) 0,02 0,6 ( 1,4) 3.600 - / POM...
  • Page 9: Design And Function

    4 Design and Function • The surface of the NED 605 and NED • The electric motor of the series NED 5016 are made of plastic. is a DC motor. • The motor shaft is made of heat- • The surface of the NED 50100 to NED treated alloyed steel.
  • Page 10: Transport And Storage

    5 Transport and Storage Check the packaging for possible shipping damage. If damage to the packaging is found, check the content for completeness and possible damage. In case of damage inform the forwarding agent. IMPORTANT The units are packed ready for The unit should be stored in a clean, installation.
  • Page 11: Installation

    6 Installation The installation of the vibrators must only be carried out by authorised, quali- fied personnel. The qualified personnel must use only tools which are suitable for the IMPORTANT application. During installation please comply strictly with the safety regulations in chapter 2 and the accident prevention rules! Installation of the system must be performed in compliance with the local, applicable regulations (e.g.
  • Page 12: Electrical Connection

    The mains voltage must comply with the nominal voltage indicated on the type plate. IMPORTANT Connection example NED The vibrators are delivered with a cable. Cable lengths: NED 605 NED 5016 NED 50100 and 50200 3,5 m NED 50500 to 2,5 m NED 601510 The electric lines have to be laid with care.
  • Page 13: Start-Up

    (after initial start-up) and then at regular intervals (as a rule, once per month). 8 Adjustment of unbalances All vibrators of the series NED (except the NED 605) provide the possibility to adjust the unbalances. Unless otherwise specified by you, the units will be shipped with the default setting (100 %).
  • Page 14 All centrifugal values in % can be adjusted as specified in the table. The removed lamella discs must be replaced by compensation washers (available from NetterVibration) of identical thickness and identical inner diameter. 2. The unbalance adjustment (coarse adjustment) is performed by turning one lamella disc on each side by 180°...
  • Page 15 Unbalance lamella discs of the type XLs Adjustment of the unbalances is carried out according to a scale disc or the supplementary sheet in the terminal box of the unit. By rotating the outer, adjustable unbalance disc(s) to another position, the percentage of the centrifugal force changes as shown in the illustration below.
  • Page 16: Trouble Shooting

    9 Trouble Shooting Faults on vibrators must only be repaired by authorised, qualified personnel. The qualified personnel must use only insulated tools suitable for the applica- tion. IMPORTANT Fault Possible cause Trouble shooting Remedy Vibrator does Carbon brushes worn out Check carbon brushes Replace carbon brushes not start or...
  • Page 17: Service / Maintenance

    Checking of the operating hours (service life of bearings) Checking of the cable supply line Other maintenance and repair work are to be carried out by NetterVibration exclusively. Authorised and specialized staff is allowed to perform the following work on the...
  • Page 18 Procedure for replacing the bearings: 1. Switch off the vibrator, secure it reliably against switching on and make sure that it is dead. 2. Unscrew socket head cap screws (1) and re- move covers (3) from the unbalances. 3. Disassembling the unbalances: •...
  • Page 19: Spare Parts

    11 Spare Parts When ordering spare parts you should always provide the following details: 1. Type of unit 2. Description and position of the spare part 3. Required quantity Example NED 50100 12 Accessories The following accessories are available for electric external vibrators of the series NED: Description Remark Compensation washers...
  • Page 20: Disposal

    Unbalance covers NED 50100 to NED 601510 steel Steel Rotor, unbalance, flange, bearing, screws, washers, nut Aluminium Housing NED 605 and NED 50100 to NED 601510, type plate, terminal box cover PTFE, PU, Seals, terminal box block VITON Copper Winding with resin All units can be disposed of through Netter GmbH.

Table of Contents