Specifications - Siemens milltronics MFA 4P Instruction Manual

Hide thumbs Also See for milltronics MFA 4P:
Table of Contents

Advertisement

Specifications

Safety
The Milltronics MFA 4p (Motion Failure Alarm) is to be used only in the manner
Note:
outlined in this manual, otherwise protection provided by the equipment may be
impaired.
Power
• 100/115/200/ 230 V AC ±15%, 50/60 Hz, 15 VA
Output
• 2 relays with Form C (S.P .D.T.) fail-safe contacts (relays operate in unison)
Resistive Rating:
• 8 A @ 250 V AC
Repeatability
• ± 1%
Temperature coefficient (setpoint variance)
• 0.018%/ °C (0.01% / °F)
Setpoint adjustment range
• 2 to 3,000 ppm (pulses per minute): standard model
• 0.15 to 15 ppm: slow speed version
Dynamic range
• 0 to 7,200 ppm