Setting The Ca Reset Groups; Checking The Wwns - Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF Configuration Manual

Fibre channel/ eternus dx500 s4/dx600 s4, eternus dx500 s3/dx600 s3, eternus dx8700 s3 hybrid storage systems, eternus dx400 s2 series, eternus dx8700 s2 disk storage systems, eternus af650 s2, eternus af650 all-flash arrays settings for bs2000 connection
Table of Contents

Advertisement

Chapter 4 Set Up the ETERNUS DX/AF Storage System for BS2000

4.7 Setting the CA Reset Groups

4.7
Setting the CA Reset Groups
All FC ports (CAs) assigned to one affinity group or referring the same LUN group must be assigned to the
same reset group.
Controller
DX/AF series
When multiple BS2000 servers share LUNs on an ETERNUS DX/AF storage system, any disk storage system CA
port that connects a shared LUN to a BS2000 server must be assigned to the same reset group, whether
multipath connections are used for the BS2000 servers or not.
If other servers than BS2000 are connected to the ETERNUS DX/AF storage system, dedicated ports for the
BS2000 servers are necessary due to different CA parameter settings (see
Fibre Channel Ports (CA Parameters)" (page
"Reset Scope: T_L" and "Reserve Cancel at Chip Reset: On" are necessary for BS2000 server connections, but
different default values are mandatory for non-BS2000 server connections.
4.8

Checking the WWNs

Use ETERNUSmgr to check the WWN of each ETERNUS DX/AF storage system CA port.
They are required to connect the ETERNUS DX/AF storage system to the server.
Controller
DX/AF series
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
Connectivity > CA Reset Group
15)):
Component > Controller Enclosure > Channel Adapters > CA
20
Copyright 2018 FUJITSU LIMITED
Category
Category
Action
Modify Reset Group
"4.2 Configuring Settings for the
Action
P3AM-5672-10ENZ0