Active Audio R80+ User Manual page 13

Ray-on+ series high directivity self-powered column loudspeakers
Table of Contents

Advertisement

5. Model selection: The model selection helps you remember which model of
Ray-On+ you are setting up.
6. Input selection: Select input you want to use.
• Analog Input: Use the balanced analog input.
• Dante Input: Use the Dante input.
• Dante / Analog fallback: If the Dante signal level is higher than -61dBFS,
the device switches to the Dante input. If the Dante signal level is less than
-61dBFS and the analog signal is higher than the analog threshold defined
(see 7.), the input switches to the analog input. If the analog signal is lower
than the analog threshold defined and the Dante signal level is less than
-61dBFS, a noisegate is activated.
7. Analog threshold: Define a SPL value between [-80 0]dB. If Dante signal is
falling down (<-61dBFS) and the analog signal level is upper than the defined
value, the device switches to its analog input.
8. Equalization selection: Enable/Disable a beep through the Dante network to
help you localize the device in your installation.
9. Mute: Enable/Disable the general output of the device. Mute is enabled when
the Master Output button is red.
10. Output gain: The output gain is a dB value between [-120 10]dB.
ver. 2018/07/26
User Manual - Ray-On+ series
13/24