    User Manual - Ray-On+ series Table of contents 1. Introduction ................4 2. Positioning .................5 3. Wiring ..................7 3.1. Example setup using Dante® ..........7 4. Ray-On+ Control software ............8 4.1. System requirements .............8 4.2. Installation on Windows ............8 4.3. Installation on OS X ..............9 4.4.
  • Page 4: Introduction

    User Manual - Ray-On+ series 1. Introduction Ray-On+ column loudspeakers ensure perfect speech intelligibility and optimal acoustical comfort, even in noisy and reverberant venues. They are based on the DGRC (Digital & Geometric Radiation Control) principle patented by Active Audio. Compared with a classic sound system in which each loudspeaker is controlled independently, the DGRC method makes it possible to decrease the number of channels to be controlled, thereby enhancing economic efficiency.
  • Page 5: Positioning

    User Manual - Ray-On+ series 2. Positioning The most important parameter for the installation of Ray-On+ loudspeaker is its mounting height because the range of the column directly depends on it. Installing the column higher will increase the range, but will affect SPL. On the contrary, installing the column lower will increase SPL, but decreases its range.
  • Page 6 User Manual - Ray-On+ series Mounting height Minimal Nominal Maximal Standing audience 1.40m 1.90m 2.40m Ray-On R80+ Seated audience 1.00m 1.50m 2.00m Standing audience 1.40m 2.10m 2.60m Ray-On R120+ Seated audience 1.00m 1.70m 2.20m Standing audience 1.60m 2.20m 2.70m Ray-On R230+ Seated audience 1.20m 1.80m...
  • Page 7: Wiring

    User Manual - Ray-On+ series 3. Wiring ANALOG I N PUT POWER SUPPLY Figure 4 : Wiring Ray-On+ columns 3.1. Example setup using Dante® Controller E t h ern et A u d i o sou rc e Et h ern et sw i t c h M at r i x M i c rop h on e rec ei ver C o n f e r e n c e r o o m...
  • Page 8: Ray-On+ Control Software

    User Manual - Ray-On+ series 4. Ray-On+ Control software The Ray-On+ control software is available for Windows and OSX operating systems. Installers can be found on the supplied USB key or on Active Audio’s website by following this link: http://www.activeaudio.fr/downloads. 4.1. System requirements...
  • Page 9: Installation On Os X

    User Manual - Ray-On+ series 4.3. Installation on OS X Start the installer package by double-clicking on it, then follow the instructions. Figure 7 : Ray-On+ Software installation on OS X ver. 2018/07/26 9/24...
  • Page 10: Using The Ray-On+ Control Software

    User Manual - Ray-On+ series 4.4. Using the Ray-On+ Control software The Ray-On+ control software gives access to the following functions: • input selection: Dante, Analog or Dante/Analog fallback • general output volume • optimized equalization for speech or music The Ray-On+ control software does not include Dante routing functionality.
  • Page 11 User Manual - Ray-On+ series 1. Network interface: Select the network corresponding to your Dante network. If you have several network interfaces, the software will select your default network interface. 2. Snapshot: Export a snapshot of your installation as a csv file by clicking on this button. The csv file contains the settings of all the devices detected on the network. 3. Device Name: The device name displayed corresponds to the device name defined in Dante Controller: Device view -> Device config -> Rename Device.
  • Page 12 User Manual - Ray-On+ series 4.4.2 Device settings A click on a Ray-On+ box leads to the settings screen for that specific column. All the parameters of the column can be changed within that screen. Figure 9 : Ray-On+ control software: column settings screen 1. Device Name: The device name displayed corresponds to the device name defined in Dante Controller: Device view -> Device config -> Rename Device.
  • Page 13 User Manual - Ray-On+ series 5. Model selection: The model selection helps you remember which model of Ray-On+ you are setting up. 6. Input selection: Select input you want to use. • Analog Input: Use the balanced analog input. • Dante Input: Use the Dante input. • Dante / Analog fallback: If the Dante signal level is higher than -61dBFS, the device switches to the Dante input.
  • Page 14 User Manual - Ray-On+ series 4.4.3 Coverage prediction Using the DGRC principle, RayOn columns generate a wave front corresponding to a desired coverage/directivity. But this directivity is fixed ; it cannot be ad- justed as in a DSP steerable column such as StepArray. Figure 10 : Ray-On+ control software: Modelling screen 1. Model selection: Select the Ray-On+ Model you want to use. 2.
  • Page 15 User Manual - Ray-On+ series ding to the user settings. You can add SPL level markers by clicking on the map. The marker’s values are automatically updated when you change one parame- ter. 5. SPL on axis: Show / Hide the SPL level vs distance on the axis. 6.
  • Page 16: Installation Of The Columns

    User Manual - Ray-On+ series 5. Installation of the columns Ray-On+ columns are mounted vertically, usually on a wall, using the supplied brackets. See also figure 11 on the next page for technical drawings of the brackets. R80+ R120+ R230+ Figure 11 : Column mounting on a wall ver.
  • Page 17: Dimensions Of The Brackets

    User Manual - Ray-On+ series It is important to ensure verticality when mounting Ray-On+ columns. 5.1. Dimensions of the brackets Figure 12 : Fixing brackets for wall mounting of Ray-On+ columns ver. 2018/07/26 17/24...
  • Page 18: Specifications

    User Manual - Ray-On+ series 6. Specifications R80+ Acoustical data Electrical data range ±3dB 6,5m amplifier type class-D amplifier range ±5dB max output power 250W max SPL 91dBSPL at 5m power consumption Idle tilting angle of audience area 0°-5° 290W frequency bandwidth (-10dB) 120Hz-17kHz opening angle at-6dB 100°...
  • Page 19: Acoustical Data

    User Manual - Ray-On+ series 7. Acoustical data All data presented below are obtained with columns in their nominal position and using nominal filtering parameters. 7.1. R80+ acoustical data Figure 13 : R80+ directivity: sound level for the voice octaves (500Hz,1kHz,2kHz) Left: horizontal, Right: vertical Figure 14 : R80+: Frequency response frequency response @1W at reference point* (left), Impedance (right) *0dB corresponds to the efficiency (dB/1W @ the reference point) ver.
  • Page 20: R120+ Acoustical Data

    User Manual - Ray-On+ series 7.2. R120+ acoustical data Figure 15 : R120+ directivity: sound level for the voice octaves (500Hz,1kHz,2kHz) Left: horizontal, Right: vertical Figure 16 : R120+: Frequency response frequency response @1W at refe- rence point* (left), Impedance (right) *0dB corresponds to the efficiency (dB/1W @ the reference point) ver. 2018/07/26 20/24...
  • Page 21: R230+ Acoustical Data

    User Manual - Ray-On+ series 7.3. R230+ acoustical data Figure 17 : R230+ directivity: sound level for the voice octaves (500Hz,1kHz,2kHz) Left: horizontal, Right: vertical Figure 18 : R230+: Frequency response frequency response @1W at refe- rence point* (left), Impedance (right) *0dB corresponds to the efficiency (dB/1W @ the reference point) ver. 2018/07/26 21/24...
  • Page 22 User Manual - Ray-On+ series ver. 2018/07/26 22/24...
  • Page 23: Declaration Of Conformity

    User Manual - Ray-On+ series 8. Declaration of conformity ACTIVE AUDIO SAS, 332 Boulevard Marcel Paul 44800 St Herblain, France, Declares under our sole responsability that the following products R80+, R120+, R230+ comply with the council directive 2004/108/CE Assessment of compliance is based on the following standards:...
  • Page 24 Active Audio SAS 332 Bd Marcel Paul, CP602 44806 Saint-Herblain Cedex - France Phone: +33 (0)2 404 666 64 Contact...