System Startup Options

The System Startup Option allows you to configure the EEC system to enter WARM Mode or Normal
RUN Mode at startup (power ON).
When turning system ON . . .
To Change System Startup Setting Follow These Steps:
ACTION
Press ACTIVE
8 times for
System Startup
Option
Press
WARM to
activate
selection
Press &
Release
ACTIVE
to cycle
through
System Startup
Options
Press
WARM to
save option
selection
Enter Configuration Mode as described in section 2.4A (pg. 29)
1
Port Neutral
2
You may continue to other configuration options
on the following pages or you may choose to
EXIT CONFIGURATION MODE by turning
system OFF, moving control handles back to
NEUTRAL, and then turn system ON again.
the transmission will
immediately respond
to the any movement of the
control head handles -
normal operation
the transmission will be locked
in WARM Mode (Neutral position)
- RPMs will be increased only
RESULT
STBD Neutral & WARM LEDs will
begin to flash
NO LEDs will be illuminated
LEDs ON
None
(locked in Neutral)
OR
(Default)
OPTION
WARM Mode
Normal RUN
Mode (Default)