Technical Specifications - Kärcher AP 100 M Service Manual

Table of Contents

Advertisement

8

Technical specifications

Main Supply
Voltage
Current type
Connected load
Protection (slow, char. C)
Type of protection
Extension cord 30 m
High-pressure pump
Power Input
Working pressure
Nozzle size
Max. operating over-pressure
Flow rate
Detergent suck in
Max. recoil force of hand spray gun
Vacuuming
Suction engine output
Cleaning power, air quantity
Cleaning power, negative pressure
Dimensions and weights
Fresh/dirt water reservoir volume
Length
Width
Height
Weight
Values determined as per EN 60355-2-79
Hand-arm vibration value
Hand spraygun
Spray lance
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
WA
BTA AP 100/50 M
ETL AP 100/50 M
Declaration of Conformity AP 100/50
M
Maintenance book AP 100/50 M
Safety instructions
pA
+ Uncertainty K
WA
Part no.:
5.963-655.0
5.971-194.0
5.957-992.0
5.950-639.0
5.956-251.0
V
Hz
kW
A
mm
2
W
MPa (bar)
MPa (bar)
l/h (l/min)
l/h (l/min)
N
W
l/s
kPa
l
mm
mm
mm
kg
m/s
2
m/s
2
m/s
2
dB(A)
dB(A)
dB(A)
9
Special tools
Description
Inner hexagon wrench (inch)
Tool box (inch)
Molex pliers
Clip-on ammeter / multimeter
English 5.906-508.0 Rev. 00 (11/10)
230
1~ 50
1,6
16
IPX5
1,5
370
0,6...1,94
(6...19,4)
0615
4,9 (49)
300 (5)
10,8 (0,18)
26
930
25
15
111/70
914
628
1092
93
< 2,5
< 2,5
0,5
79
3
95
Part no.:
6.815-032.0
6.816-079.0
6.816-086.0
6.803-022.0
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap 50 m