Pioneer YN-M Series Installation Manual page 10

Multi-split system air conditioner / heat pump. inverter++ models two, three, four, and five zones (dual, triple, quad, and quint multi)
Hide thumbs Also See for YN-M Series:
Table of Contents

Advertisement

Split Type Outdoor Unit
(Refer to Fig 6.4, 6.5, 6.6, 6.10 and Table 6.1)
W
Fig. 6.4
W
Fig. 6.5
A
D
Fig. 6.6
Page 10
Table 6.1: Length Specifications of Split Type
Outdoor Unit Dimensions
2 Zone (Dual Multi Split)
845x702x363 (33-1/4x27-5/8/14-3/8)
H
3 Zone (Triple Multi Split)
946x810x420 (37-1/4x31-7/8x16-1/2)
4 Zone (Quad Multi Split)
946x810x420 (37-1/4x31-7/8x16-1/2)
5 Zone (Quint Multi Split)
952x1333x415 (37-1/2x52-1/2x16-1/4) 634 (25)
Installation in Rows (Parallel or Serial)
H
Table 6.2 The relations between H, A, and L
L ≤ H
L > H
B
Outdoor Unit (unit: mm/inch)
Mounting Dimensions
W x H x D
Distance A
540 (21-1/4)
673 (26-1/2)
673 (26-1/2)
are as follows:
L
25 cm / 10" or more
L ≤ 1/2H
1/2H < L ≤ H
30 cm / 12" or more
Cannot be installed
H
Fig. 6.7
Distance B
350 (13-3/4)
403 (15-7/8)
403 (15-7/8)
404 (15-7/8)
A
L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents