Outdoor Unit Installation

Outdoor Unit Installation Instructions

Step 1: Select installation location.
The outdoor unit should be installed at a location
in accordance with the following guidelines:
Place the outdoor unit as close to the indoor
units as possible.
Ensure that there is enough room for
installation and maintenance.
The air inlet and outlet must not be
obstructed or exposed to strong winds.
Ensure the location of the unit will not be
subject to snowdrifts, accumulation of leaves,
or other seasonal debris. If possible, provide
an awning for the unit. Ensure the awning
does not obstruct the airflow.
The installation area must be dry and well
ventilated.
There must be enough room to install the
connecting pipes and cables, and to access
them for maintenance.
Strong wind
Fig. 6.1
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10 or 3/8")
>60cm / 24"
Fig. 6.3
Strong wind
(Alternatively, use condenser
Wall Mounting Brackets)
Fix with bolts
The area must be free of combustible gases
and chemicals.
The pipe length between the outdoor and
indoor unit may not exceed the maximum
allowable pipe length.
If possible, DO NOT install the unit where it
is exposed to direct sunlight.
If possible, make sure the unit is located far
away from your neighbors' property so that
the noise from the unit will not disturb them.
If the location is exposed to strong winds (for
example: near a seaside), the unit must be
placed against the wall to shelter it from the
wind. If necessary, use an awning.
(See Fig. 6.1 & 6.2)
Install the indoor and outdoor units, cables
and wires at least 1 meter from televisions or
radios to prevent static or image distortion.
Depending on the radio waves, a 1m (3')
distance may not be enough to eliminate all
interference.
Fig. 6.2
CAUTION
Be sure to remove any obstacles that
may block air circulation.
Make sure you refer to length
specifications to ensure there is
enough room for installation and
maintenance.
6
Minimum clearance
needed in front of the
unit is 2m (80 Inches)
Strong wind
Page 9