4
(2) Structure and manipulation – Components
Ignition Reset
Button
Controls the amount and speed of hot air coming
Damper
into the drum
"0" with the least amount air to be come into and "10"
with he most
1) Control the amount of heat inside the drum
2) Discharge used coffee grounds and smoke during
roasting
3) Hold/ discharge aroma during roasting
Timer
Equipment to program pre-heat time or roasting
time
The upper number shows the current time and the
one below shows set time
How to set : Press ◀ to move the cursor and ▲ ▼
to increase / decrease numbers
Finalize your setting by pressing MD button
Knob
Equipment to control heating power during roasting
Make the gas gage standard and control sensitively
(Gas gage should be the heating standard because the gas
pressures are different according to places and conditions)
Equipment to control discharge
Inverter
The rest numbers except the part forced to change
become vague when you press ENT
How to set : Press ◀ to move the cursor and ▲ ▼ to
increase / decrease numbers
Finalize your setting by pressing ENT button
0(Maximum discharge) < 60 (Minimum discharge)
Function of resetting automatic ignition equipment
Press the reset button when the red light is on m which means
that ignition fails because of the air inside of gas pipe.
※ Press reset and ignition button repeatedly until empty air
inside its gas pipe when ignition fails