Download Print this page

Proaster THCR-12 User Manual page 6

Advertisement

2
2) Emergency Stop Switch
-This button is used to prevent exposure to heat and electricity in case of
emergency
- Do not stop the drum or blower when the machine is overheated. Doing so may
cause a fire or breakdown
- The drum will keep working after emergency button is pressed
- Do not stop the drum or blower when they are overheated. The machine's
special design makes fire or breakdown likely if the drum is completely stopped.
3) Overheating protection device
-Once roasting temperature on the product's temperature display window reaches
the preset temperature, the heat supply is cut off to avoid overheating
-Do not reset the temperature above the originally pre-programmed temperature.
Otherwise, the machine will overheat.
4) Overflowing voltage protection system
- Power shuts off in the event of electrical malfunctions (short circuit, etc.)
5) Fire extinguishing safety device :
and automatically shuts off gas when power is off
6) Short circuit protection device : Users should contact their own Gas maintenance
company
3
(1) Carrying the product
1) Package
-
For export machines, first remove nails from the
wooden container and take out slats and
boards. Please recycle packaging materials in
accordance with your country's regulations.
-
Please confirm that the roaster unit, filter
cyclone 2, instruction manual, and tool kit have
been included.
2) How to carry
-
Weight: about 500 kg
-
Method: use a forklift to transport over level
ground. Be sure to keep a close, firm hold on
the bottom part of the machine.
Consumer safety device prevents overheating