Electrical Connection
Always refer to the wiring diagrams when connecting equipment electrical utilities
1. The CBS-2100XTS series models requires hardwire to the terminal block to a, grounded service
2. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the
brewer's serial number label. Make sure the electrical service match the current draw of the equipment.
3. All CBS-2100XTS equipment have a terminal block for connecting the incoming power wires.
4. Consult local codes to determine if a cord and plug can be installed on factory supplied terminal block
equipment, or if the unit must be hard wired.
5. Access the terminal block for electrical connection by removing the pullout service module on the lower back.
6. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the
brewer, and its location and markings known to the operators.
7. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters
during the installation process. The heaters are disabled by the control board until the tank is full of water. The
heating process will start automatically when the tank has filled.
8. The body of the brewer must be grounded to a suitable building ground.
9. An equipotential bonding point is provided for thisd connection where it is required.
Tank Drain
The water tank must be drained before maintenance procedures, and when the unit is to be relocated or shipped
1. Disconnect power to unit.
2. Move the unit near a sink or obtain a container large enough to hold four gallons of water and a hose clamp.
Note that the tank may hold more than four gallons and that the drain line will be clamped to empty the
container.
3. Remove the tank cover and allow the tank to cool to a safe temperature
4. The tank drain is located on the back of the unit. Turn the drain plug one-quarter turn in either direction
5. Pull the plug out far enough to expose the silicone tube
6. Using pliers loosen the hose clamp and move it back over the tube.
7. Crimp the tube an inch or two away from the drain plug to prevent water from flowing.
8. Use the other hand to pull the drain plug out of the tube.
9. Release the crimped tube and allow the water to flow into the sink or container.
10. Multiple buckets may be needed during the draining, see tank volumes below.
Brewer &
Hot Water
Brew Volume
Tank Capacity
CBS-2161
Single-12 liter
37.3 liter
CBS-2162
Dual-12 liter[x2]
67.8 liter
Go to fetco.com for the latest version of all information
See wiring diagrams for connections
9.9 gal
17.9 gal
17