Key free smart lock with touchscreen keypad (1 page)
Summary of Contents for Yale YRDZB
Page 1
IC: 6982A-YRHCPZB0 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0001 Manufacturer: Assa Abloy Inc. Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB Manual – YRT220-ZB 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598...
Page 2
COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For Technical Assistance call Yale at 1-800-810-WIRE (9473) This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com. Click "Product Information & Documentation" and then "Installation Instructions".
Sample Pin Code Management Sheets ............23-24 WARNINGS Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc. could void the user's authority to operate the equipment. IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and security of this product.
Page 4
To reset the lock to factory default, see the following: Reset Lock to Factory Default Reset Button The following procedure returns the lock to its factory defaults by deleting all user codes (including the Master PIN code*) and returning all programming features to their original default settings (see below).
INSTALL LOCK Install Latch The lock is packed representative of how it will install on the door. Before installing the lock on the door: A. Remove the latch (Fig. 1) and strike plate from the packaging. NOTE: Latch ships with backset in 2-3/8" position (Fig. 1). Backset is the measurement from door edge to center of 2-1/8"...
Page 8
Install Outside Escutcheon NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to indicate their orientation for proper installation (Figures A & B). NOTE: RED marking indicates "top" of hub Clip Shank Square Drive Tube is marked...
Page 9
Install Outside Escutcheon 2. Remove the inside mounting plate (with gasket) from the back (door side) of the inside escutcheon (Fig. 2A). A. Ensure that gasket on inside mounting plate is properly fitted (Fig. 2B). Figure 2A Inside Escutcheon & Mounting Plate Figure 2B (with gasket) 3.
Page 10
7. Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up notches on top of cable connector to slots on PCB connector (Fig. 7A & 7B). Press connector in firmly using thumbs until completely seated (properly seated position indicated by arrows on PCB as in Fig.
Page 11
Determine Lever Handing Hinges on Right Hinges on Left Right handed Left handed lever position lever position Lever Lever Both outside and inside lever handles should always point toward the door hinges. Determine Lever Position Correct "curved" position Correct "curved" position Incorrect Incorrect Before proceeding with the next step, ensure correct lever handing for proper installation.
Page 12
Install the Exterior Lever (Right Hand shown) 1. Install cylinder in exterior lever. Tailpiece (If necessary, remove key from cylinder) A. Drop cylinder in exterior lever handle as shown. Figure 1A B. Insert key in cylinder. While supporting cylinder tailpiece (with finger); rotate key 90°...
Page 13
E. Push lever handle (with key & cylinder) over shank until hole on handle aligns with set screw in shank (Figure 1E). Figure 1E F. Secure lever handle by inserting allen wrench and rotating set screw CCW (Fig. 1F). Do not overtighten. G.
Page 14
Install the Exterior Lever (Right Hand shown) 1. Rotate thumbturn counter-clockwise to horizontal position (Fig. 9A). Figure 9A 3. Turn set screw CCW to tighten 2. Insert set screw on side of shank (toward edge of door); turn CW to allow placement and secure lever handle to shank.
PROGRAMMING Programming Features-Menus-Keys-Definitions ..........12-13 Operation ......................14-17 PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS Outside Inside " P " Key Phillips Screw Touch Screen (Return to Previous) Battery Cover Network Module Slot Numbers Low Battery Alkaline Batteries Indicator 4 AA Type Lockout Mode Status Indicator...
Page 16
Status Indicators Low Battery Warning Lockout Mode Return to previous step Definitions Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE;...
OPERATION Lock Activation The touchscreen can be activated in several ways: Touch lock with Press the key to Touch lock with back of hand or activate. fingers spread to fingers to activate. activate. Lock Operation Master Code Set* 1. Touch the screen with the back of your hand or fingers to activate 2.
Page 18
PIN code structure Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. Set Up User PIN Codes User PIN Codes can only be programmed through the Master PIN Code*. 1. Touch the screen with the back of your hand or fingers to activate 2.
Page 19
Feature Programming Through Menu Mode Using Master PIN code* 1. Touch the screen with the back of your hand or fingers to activate 2. Enter the 4-8 digit Master PIN code* followed by the key. Lock Response: “Menu mode, enter number, press the key to continue.”...
MISCELLANEOUS Hardware Troubleshooting ..................17 Programming Troubleshooting ................18 Installing the Network Module ................19 Change Lever Handing ..................20-21 Replace/Install Cylinder ..................22 Sample Pin Code Management Sheets ............23-24 TROUBLESHOOTING Hardware Troubleshooting Cycle the lock in both the locked and the unlocked positions. If problems are found: Symptom Suggested Action Door is binding...
Programming Troubleshooting Symptom Suggested Action Lock does not respond – door is open and The touchscreen will become active when pressed with the back of hand or fingers in at least 3 areas accessible. simultaneously. Use a larger area of the hand or fingers and verify contact with at least 3 areas. If touchscreen numbers are visible, check to see if they respond when pressed.
Installing the Network Module IMPORTANT: The batteries must be removed prior to removing and/or inserting the network module: • Remove batteries • Remove and/or insert network module • Reinstall batteries Use Feature Programming step 7 (page 16) for enrollment of the Network Module. P/N AYRT-220-INST-FUL Rev A An ASSA ABLOY Group brand...
Page 23
How to Change Handing of Lever (Reverse Levers) 1. Remove the outside lever handle: A. Insert key in cylinder (outside lever handle); rotate key 90° clockwise. B. Insert allen wrench (included) in set screw on side of lever (toward edge of door);...
Page 24
2. Remove the inside lever handle: A. Insert allen wrench (included) in set screw on side of lever (towards edge of door); turn clockwise to loosen lever handle. B. Pull to remove lever handle. 3. Change the lever handing: A. Remove and switch handles (inside to outside, outside to inside). B.
Page 25
How to Replace or Install Cylinder 1. Remove cylinder: A. Repeat previous steps for removing the outside lever handle. B. Remove cylinder. 2. Install new cylinder: A. Insert cylinder in "new" outside lever. B. Push handle in allowing holes for set screw to align. C.
Page 26
PIN CODE MANAGEMENT SAMPLE SHEETS PIN Code Management (No Network Module - Up to 25 Users) Location: Door Number: User User Name User # PIN Code User Type User Name User # PIN Code Master User 13 User 01 User 14 User 02 User 15 User 03...
Page 27
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries User Type User Name User # PIN Code User User Name User # PIN Code Master User ___ User ___ User ___ User ___ User ___ User ___ User ___...
Need help?
Do you have a question about the YRDZB and is the answer not in the manual?
Questions and answers