1
P/N
AYRD 156-INST FUL
-
YRD156
®
x3
#8-32 x 5/16"
Machine screws
OR
x2 Gold
x2 Black
M6x36mm
M6x44mm
PPHMS
PPHMS
(1-3/8" )
(Standard 1-3/4" - 2" )
-
Rev A
x4
#7 wood & #8-32
machine x 20mm
Combination screws
OR
x2 Silver
M6x55mm
PPHMS
(2-1/4" )

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Real Living YRD156 and is the answer not in the manual?

Questions and answers

Summary of Contents for Yale Real Living YRD156

  • Page 1 Yale Real Living YRD156 ® Key Free Touchscreen Deadbolt with Z-Wave Plus ® Installation and Programming Instructions Before you begin #7 wood & #8-32 DOWNLOAD #8-32 x 5/16" machine x 20mm Machine screws Combination screws THE BILT APP for step-by-step installation instructions &...
  • Page 2 Preparing Door and Touchscreen Escutcheon Cup must be removed from escutcheon if bore hole is less than 2-1/8". 2-1/8" Application <2-1/8" Application AYRD 156-INST FUL Rev A...
  • Page 3 Installing Latch & Strike Plate 2-3/8" position default 2- / 2-3/4" position optional 2- / 2- / Rotate Bolt must be in retracted (unlocked) position. UP arrow must be facing upwards. AYRD 156-INST FUL Rev A...
  • Page 4 Installing Touchscreen Escutcheon If bore hole is less than 2-1/8", remove cup by gently compressing two tabs while pulling. Outside of Door Ensure cable is routed under the deadbolt. AYRD 156-INST FUL Rev A...
  • Page 5 Installing Interior Mounting Plate Choose through bolt appropriate for your door thickness. AYRD 156-INST FUL Rev A...
  • Page 6 Attaching the Cable Assembly AYRD 156-INST FUL Rev A...
  • Page 7 Installing Interior Escutcheon Thumbturn should be in vertical position. AYRD 156-INST FUL Rev A...
  • Page 8 Testing Operation Deadbolt should extend and retract smoothly. If not, go back to step 2. Bolt must be in retracted (unlocked) position before installing AA batteries. AYRD 156-INST FUL Rev A...
  • Page 9 Initial Programming Press Enter new Master PIN code (4-8 digits). Press to complete. Lock will not operate until gear is pressed and Master PIN code is set. After entering the Master PIN code, press any key to complete handing. AYRD 156-INST FUL Rev A...
  • Page 10 Installing Cover ® Congratulations, you've installed the Yale Real Living YRD156 Key Free Touchscreen Deadbolt with Z-Wave Plus! Continue with Programming Instructions to customize your product. AYRD 156-INST FUL Rev A...
  • Page 11 Programming Instructions Touchscreen Wake-Up All Code Lockout Mode Rapidly beeps 5 times Low Battery Warning Flashes RED Failsafe 9 Volt Battery Connection (Use Alkaline battery) Master Code must be created before any further programming. Max User Codes = 250 in network Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user's authority to operate the equipment.
  • Page 12 Changing Master Code Enter Master code Press Press Press Press Enter 4-8 digit Master Code. Press AYRD 156-INST FUL Rev A...
  • Page 13 Creating User Codes Master code must be created first. Max User Codes = 250 in network Press Enter Master code Press Press Press Press Enter 4-8 digit code Press Press AYRD 156-INST FUL Rev A...
  • Page 14 Unlocking Door with Code Press Enter PIN Press "Unlock" Code Chart Duplicate if necessary PIN Code Management - Up to 250 Users (in network) User Name PIN Code AYRD 156-INST FUL Rev A...
  • Page 15 Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see "Factory Default Settings"). 1. Remove the battery cover. 2.
  • Page 16 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the lock rapidly beeps 5 times. Audio Mode: Choosing Disable (3)
  • Page 17 Feature Programming Through Menu Mode Using Master code* 1. Wake the lock by pressing the key. 2. Enter the 4-8 digit Master PIN code followed by the 3. Enter digit corresponding to the function to be performed followed by the key.
  • Page 18 Programming Troubleshooting Symptom Suggested Action AYRD 156-INST FUL Rev A...
  • Page 19 Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user's authority to operate the equipment. FCC: Industry Canada: Contain FCC ID: 2ABFG- YRIZW2USTS1 Contain 11626A- YRIZW2USTS1 Model: YRD156-ZW-619,605,0BP Model: YRD156-ZW-619,605,0BP This equipment has been tested and found to comply Section 7.1.2 of RSS GEN Under Industry Canada with the limits for a Class B digital device, pursuant...
  • Page 20 Product Support Tel 1-855-213-5841 • www.yalehome.com Yale and Yale Real Living are registered trademarks of ASSA ABLOY Residential Group. Other products' brand ® ® names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.
  • Page 21 Yale Locks Z-Wave Plus System Integrators Guide Yale YRD156...
  • Page 22 Contents Yale Z-Wave Plus Product Info ........................3 Supported Command Classes ........................3 Association Table ............................ 3 Notifications Table ..........................4 Configurable Parameters ......................... 6...
  • Page 23 Yale Z-Wave Plus Product Info Manufacturer ID: Assa Abloy (0x0129) Z-Wave Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) Product ID: 0x0508 Product Type ID: 0x803A – YRD156-ZW2 (Touchscreen Deadbolt) Supported Command Classes Command Class Z-Wave Plus Info...
  • Page 24 Notifications Table Alarm Alarm Reports Alarm Level Description type 0x00 Master code was changed at keypad Master Code changed. 0xFB Master code was changed over RF 0x70 0x(01-max User added User added. Alarm level = user slot number users) 0x(01-max User deleted 0x21 User was deleted.
  • Page 25 Enabled/Disabled users) ** - The Yale YRD156 also supports a 3 low battery alarm, too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery...
  • Page 26 Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 3 = Silent. Default is 1 Silent mode on/off 1 1 byte or High Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 10 to 180 seconds default is 30 seconds...